Hook-calibration of GeneChip-microarrays: Chip characteristics and expression measures

被引:17
作者
Binder, Hans [1 ]
Krohn, Knut [2 ]
Preibisch, Stephan [3 ]
机构
[1] Univ Leipzig, Interdisciplinary Ctr Bioinformat, D-04107 Leipzig, Germany
[2] Univ Leipzig, Fac Med, Interdisciplinary Ctr Clin Res, D-04107 Leipzig, Germany
[3] Max Planck Inst Mol Cell Biol & Genet, D-01307 Dresden, Germany
关键词
D O I
10.1186/1748-7188-3-11
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Microarray experiments rely on several critical steps that may introduce biases and uncertainty in downstream analyses. These steps include mRNA sample extraction, amplification and labelling, hybridization, and scanning causing chip-specific systematic variations on the raw intensity level. Also the chosen array-type and the up-to-dateness of the genomic information probed on the chip affect the quality of the expression measures. In the accompanying publication we presented theory and algorithm of the so-called hook method which aims at correcting expression data for systematic biases using a series of new chip characteristics. Results: In this publication we summarize the essential chip characteristics provided by this method, analyze special benchmark experiments to estimate transcript related expression measures and illustrate the potency of the method to detect and to quantify the quality of a particular hybridization. It is shown that our single-chip approach provides expression measures responding linearly on changes of the transcript concentration over three orders of magnitude. In addition, the method calculates a detection call judging the relation between the signal and the detection limit of the particular measurement. The performance of the method in the context of different chip generations and probe set assignments is illustrated. The hook method characterizes the RNA-quality in terms of the 3'/5'-amplification bias and the sample-specific calling rate. We show that the proper judgement of these effects requires the disentanglement of non-specific and specific hybridization which, otherwise, can lead to misinterpretations of expression changes. The consequences of modifying probe/target interactions by either changing the labelling protocol or by substituting RNA by DNA targets are demonstrated. Conclusion: The single-chip based hook-method provides accurate expression estimates and chip-summary characteristics using the natural metrics given by the hybridization reaction with the potency to develop new standards for microarray quality control and calibration.
引用
收藏
页数:26
相关论文
共 53 条
[1]  
*AFF, SPIK IN DAT SET
[2]  
*AFF, 2003, GENECHIP HUM GEN U13
[3]  
*AFF, 2004, IVT LAB KIT TECHNICA, P1
[4]  
*AFF, 2005, GENECHIP EXPR PLATF
[5]  
*AFF, 2001, ARR DES GENECHIP HUM
[6]  
*AFF, 2002, STAT ALG DESCR DOC, P28
[7]  
*AFF, 2004, GENECHIP YEAST GEN 2
[8]   Chipping away at the chip bias: RNA degradation in microarray analysis [J].
Auer, H ;
Lyianarachchi, S ;
Newsom, D ;
Klisovic, MI ;
Marcucci, U ;
Kornacker, K .
NATURE GENETICS, 2003, 35 (04) :292-293
[9]   DNA, RNA and hybrid RNA-DNA oligomers of identical sequence: structural and dynamic differences [J].
Barone, F ;
Cellai, L ;
Matzeu, M ;
Mazzei, F ;
Pedone, F .
BIOPHYSICAL CHEMISTRY, 2000, 86 (01) :37-47
[10]   Base pair interactions and hybridization isotherms of matched and mismatched oligonucleotide probes on microarrays [J].
Binder, H ;
Preibisch, S ;
Kirsten, T .
LANGMUIR, 2005, 21 (20) :9287-9302