Confocal reflectance theta line scanning microscope for imaging human skin in vivo

被引:72
作者
Dwyer, PJ
DiMarzio, CA
Zavislan, JM
Fox, WJ
Rajadhyaksha, M
机构
[1] Northeastern Univ, Dept Elect Engn, CenSSIS, Boston, MA 02115 USA
[2] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[3] Lucid Inc, Rochester, NY 14623 USA
[4] Mem Sloan Kettering Canc Ctr, Dept Med, Dermatol Serv, New York, NY 10022 USA
关键词
D O I
10.1364/OL.31.000942
中图分类号
O43 [光学];
学科分类号
070207 [光学]; 0803 [光学工程];
摘要
A confocal reflectance theta line scanning microscope demonstrates imaging of nuclear and cellular detail in human epidermis in vivo. Experimentally measured line-spread functions determine the instrumental optical section thickness to be 1.7 +/- 0.1 mu m and the lateral resolution to be 1.0 +/- 0.1 mu m. Within human dermis (through full-thickness epidermis), the measured section thickness is 9.2 +/- 1.7 mu m and the lateral resolution is 1.7 +/- 0.1 mu m. An illumination line is scanned directly in the pupil of the objective lens, and the backscattered descanned light is detected with a linear array, such that the theta line scanner consists of only seven optical components. (c) 2006 Optical Society of America.
引用
收藏
页码:942 / 944
页数:3
相关论文
共 8 条
[1]
INVIVO VISION OF THE HUMAN SKIN WITH THE TANDEM SCANNING MICROSCOPE [J].
CORCUFF, P ;
LEVEQUE, JL .
DERMATOLOGY, 1993, 186 (01) :50-54
[3]
INVIVO IMAGING OF HUMAN TEETH AND SKIN USING REAL-TIME CONFOCAL MICROSCOPY [J].
NEW, KC ;
PETROLL, WM ;
BOYDE, A ;
MARTIN, L ;
CORCUFF, P ;
LEVEQUE, JL ;
LEMP, MA ;
CAVANAGH, HD ;
JESTER, JV .
SCANNING, 1991, 13 (05) :369-372
[4]
In vivo confocal scanning laser microscopy of human skin II:: Advances in instrumentation and comparison with histology [J].
Rajadhyaksha, M ;
González, S ;
Zavislan, JM ;
Anderson, RR ;
Webb, RH .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1999, 113 (03) :293-303
[5]
IN-VIVO CONFOCAL SCANNING LASER MICROSCOPY OF HUMAN SKIN - MELANIN PROVIDES STRONG CONTRAST [J].
RAJADHYAKSHA, M ;
GROSSMAN, M ;
ESTEROWITZ, D ;
WEBB, RH .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1995, 104 (06) :946-952
[6]
Video-rate confocal scanning laser microscope for imaging human tissues in vivo [J].
Rajadhyaksha, M ;
Anderson, RR ;
Webb, RH .
APPLIED OPTICS, 1999, 38 (10) :2105-2115
[7]
FUNDAMENTAL REDUCTION OF THE OBSERVATION VOLUME IN FAR-FIELD LIGHT-MICROSCOPY BY DETECTION ORTHOGONAL TO THE ILLUMINATION AXIS - CONFOCAL THETA MICROSCOPY [J].
STELZER, EHK ;
LINDEK, S .
OPTICS COMMUNICATIONS, 1994, 111 (5-6) :536-547
[8]
Confocal microscope with large field and working distance [J].
Webb, RH ;
Rogomentich, F .
APPLIED OPTICS, 1999, 38 (22) :4870-4875