Comparison of uncertainties related to standardization of urine samples with volume and creatinine concentration

被引:77
作者
Garde, AH
Hansen, ÅM
Kristiansen, J
Knudsen, LE
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Inst Publ Hlth, Dept Pharmacol, DK-2200 Copenhagen, Denmark
关键词
bias; standardization; uncertainty; urine;
D O I
10.1093/annhyg/meh019
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 [公共卫生与预防医学]; 120402 [社会医学与卫生事业管理];
摘要
When measuring biomarkers in urine, volume (and time) or concentration of creatinine are both accepted methods of standardization for diuresis. Both types of standardization contribute uncertainty to the final result. The aim of the present paper was to compare the uncertainty introduced when using the two types of standardization on 24 h samples from healthy individuals. Estimates of uncertainties were based on results from the literature supplemented with data from our own studies. Only the difference in uncertainty related to the two standardization methods was evaluated. It was found that the uncertainty associated with creatinine standardization (19-35%) was higher than the uncertainty related to volume standardization (up to 10%, when not correcting for deviations from 24 h) for 24 h urine samples. However, volume standardization introduced an average bias of 4% due to missed volumes in population studies. When studying a single 24 h sample from one individual, there was a 15-20% risk that the sample was incomplete. In this case a bias of similar to25% was introduced when using volume standardization, whereas the uncertainty related to creatinine standardization was independent of the completeness of the sample. The uncertainty of creatinine standardization is increased when studying single voids rather than 24 h urine samples. This is partially counteracted by the increased statistical power due to the increased number of samples for each individual. Furthermore, there is a considerable increase in convenience for the participants, when collecting small volumes rather than complete 24 h samples.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 40 条
[1]
Biomarkers for exposure to ambient air pollution - Comparison of carcinogen-DNA adduct levels with other exposure markers and markers for oxidative stress [J].
Autrup, H ;
Daneshvar, B ;
Dragsted, LO ;
Gamborg, M ;
Hansen, AM ;
Loft, S ;
Okkels, H ;
Nielsen, F ;
Nielsen, PS ;
Raffn, E ;
Wallin, H ;
Knudsen, LE .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 (03) :233-238
[2]
BAILEY RR, 1970, LANCET, V1, P145
[3]
BARTELS H, 1971, CLIN CHIM ACTA, V32, P81, DOI 10.1016/0009-8981(71)90467-0
[4]
BINGHAM SA, 1985, HUM NUTR-CLIN NUTR, V39C, P343
[5]
INFLUENCE OF EXERCISE ON UREA, CREATININE, AND 3-METHYLHISTIDINE EXCRETION IN NORMAL HUMAN-SUBJECTS [J].
CALLESESCANDON, J ;
CUNNINGHAM, JJ ;
SNYDER, P ;
JACOB, R ;
HUSZAR, G ;
LOKE, J ;
FELIG, P .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (04) :E334-E338
[6]
CREATININE EXCRETION - DIURNAL VARIATION AND VARIABILITY OF WHOLE AND PART-DAY MEASURES - A METHODOLOGIC ISSUE IN PSYCHOENDOCRINE RESEARCH [J].
CURTIS, G ;
FOGEL, M .
PSYCHOSOMATIC MEDICINE, 1970, 32 (04) :337-&
[7]
SERIAL CHANGES IN 24-HOUR CREATININE CLEARANCE DURING NORMAL MENSTRUAL CYCLES AND THE FIRST TRIMESTER OF PREGNANCY [J].
DAVISON, JM ;
NOBLE, MCB .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1981, 88 (01) :10-17
[8]
DEWARDENER HE, 1985, KIDNEY OUTLINE NORMA, P39
[9]
EDWARDS KDG, 1959, CLIN SCI, V18, P361
[10]
EDWARDS OM, 1969, LANCET, V2, P1165