Pulmonary nodules: Experimental and clinical studies at low-dose CT

被引:135
作者
Diederich, S
Lenzen, H
Windmann, R
Puskas, Z
Yelbuz, TM
Henneken, S
Klaiber, T
Eameri, M
Roos, N
Peters, PE
机构
[1] Univ Munster, Inst Clin Radiol, D-48129 Munster, Germany
[2] Univ Munster, Gerhard Domagk Inst Pathol, D-48129 Munster, Germany
关键词
computed tomography (CT); comparative studies; experimental studies; radiation exposure; lung; nodule; lung neoplasms; CT; diagnosis;
D O I
10.1148/radiology.213.1.r99oc29289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the number of pulmonary nodules detected at helical low- and standard-dose computed tomography (CT) and to investigate the diagnostic value of low-dose CT with a radiation exposure equivalent to that used at chest radiography. MATERIALS AND METHODS: Two radiologists recorded pulmonary nodules at standard-dose (250 or 100 mA, pitch of 1; 200 mA, pitch of 2) or low-dose CT (50 or 25 mA, pitch of 1 or 2) in five postmortem specimens and 75 patients. Nodules were assessed by size (5 mm or smaller, 6-10 mm, or larger than 10 mm) and by diagnostic confidence ("definite nodute," "definite lesion, not classic nodule" or "questionable lesion, possibly representing a vessel") with the Wilcoxon signed rank: test. Artifacts depicted at low-dose CT were recorded. RESULTS: There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT except in nodules 5 mm or smaller that were assessed as definite nodules at standard- or low-dose CT (25 mA, pitch of 2) (472 vs 397, P <.05). Artifacts that possibly interfered with nodule detection were-observed exclusively at CT with 25 mA and a pitch of 2. CONCLUSION: Pulmonary nodules were detected reliably at CT:with 50 mA and pitch of 2 or with 25 mA and a pitch of 1. However, further reduction of the dose to that used at chest radiography was associated with a significant :decrease in the number of nodules 5 mm Or smaller that were detected, possibly due to artifacts.
引用
收藏
页码:289 / 298
页数:10
相关论文
共 35 条
  • [1] FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST
    AMBROSINO, MM
    GENIESER, NB
    ROCHE, KJ
    KAUL, A
    LAWRENCE, RM
    [J]. PEDIATRIC RADIOLOGY, 1994, 24 (01) : 6 - 10
  • [2] Pulmonary arteriovenous malformations
    Coley, SC
    Jackson, JE
    [J]. CLINICAL RADIOLOGY, 1998, 53 (06) : 396 - 404
  • [3] COMPARISON OF SPIRAL-ACQUISITION COMPUTED-TOMOGRAPHY AND CONVENTIONAL COMPUTED-TOMOGRAPHY IN THE ASSESSMENT OF PULMONARY METASTATIC DISEASE
    COLLIE, DA
    WRIGHT, AR
    WILLIAMS, JR
    HASHEMIMALAYERI, B
    STEVENSON, AJM
    TURNBULL, CM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797) : 436 - 444
  • [4] PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT
    COSTELLO, P
    ANDERSON, W
    BLUME, D
    [J]. RADIOLOGY, 1991, 179 (03) : 875 - 876
  • [5] DAVIS SD, 1991, RADIOLOGY, V180, P1
  • [6] DREXLER G, 1990, CALCULATION DOSE EXT, V3
  • [7] MATCHMAKING AND MCNEMAR IN THE COMPARISON OF DIAGNOSTIC MODALITIES
    DWYER, AJ
    [J]. RADIOLOGY, 1991, 178 (02) : 328 - 330
  • [8] PULMONARY NODULES IN SPIRAL VOLUMETRIC AND SINGLE SLICE COMPUTED-TOMOGRAPHY
    FRIESE, SA
    RIEBER, A
    FLEITER, T
    BRAMBS, HJ
    CLAUSSEN, CD
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 (01) : 48 - 51
  • [9] Pulmonary nodules: detection with low-dose vs conventional-dose spiral CT
    Gartenschlager, M
    Schweden, F
    Gast, K
    Westermeier, T
    Kauczor, HU
    von Zitzewitz, H
    Thelen, M
    [J]. EUROPEAN RADIOLOGY, 1998, 8 (04) : 609 - 614
  • [10] COMPARISON OF 2 METHODS FOR ASSESSING PATIENT DOSE FROM COMPUTED-TOMOGRAPHY
    GELEIJNS, J
    VANUNNIK, JG
    ZOETELIEF, J
    ZWEERS, D
    BROERSE, JJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (796) : 360 - 365