Nonstationarity broadening reduction in pulsed Doppler spectrum measurements using time-frequency estimators

被引:40
作者
Cardoso, JCS
Ruano, MG
Fish, PJ
机构
[1] UNIV COLL N WALES, SCH ELECT ENGN & COMP SYST, BANGOR LL57 1UT, GWYNEDD, WALES
[2] UNIV ALGARVE, UNIDAD CIENCIAS EXACTAS & HUMANAS, P-8000 FARO, PORTUGAL
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1109/10.544341
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The spectral width of Doppler signals is used as measure of lesion-induced flow disturbance. Its estimation accuracy is compromised using the conventional short-term Fourier transform (STFT) since this method implicitly assumes signal stationarity during the signal window while the Doppler signals from arteries are markedly nonstationary. The Wigner-Ville (WVD), Choi-Williams (CWD) and Bessel distributions (BD), specifically designed for nonstationary signals, have been optimized for spectral width estimation accuracy and compared to the STFT under different signal to noise ratios using simulated Doppler signals of known time-frequency characteristics. The optimum parameter values for each method were determined as a Hanning window duration of 10 ms for the SFTF, 40 ms for the WVD and CWD and 20 ms for the BD and dimensionless time-frequency smoothing constant values of five in the CWD and two in the BD. Thresholding was used to reduce the effect of cross terms and side lobes in the WVD and BD. With no added noise the WVD gave the lowest estimation error followed by the CWD. At signal-to-noise ratios (SNR's) of 10 dB and 20 dB the CWD and BD had similar errors and were markedly better than the other estimators. Overall the CWD gave the best performance.
引用
收藏
页码:1176 / 1186
页数:11
相关论文
共 23 条
[1]   THEORETICAL-STUDY OF THE SCATTERING OF ULTRASOUND FROM BLOOD [J].
ANGELSEN, BAJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (02) :61-67
[2]   AN EFFICIENT REAL-TIME IMPLEMENTATION OF THE WIGNER VILLE DISTRIBUTION [J].
BOASHASH, B ;
BLACK, PJ .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1987, 35 (11) :1611-1618
[3]  
BRODY WR, 1974, IEEE T BIO-MED ENG, VBM21, P183, DOI 10.1109/TBME.1974.324381
[4]   IMPROVED TIME-FREQUENCY REPRESENTATION OF MULTICOMPONENT SIGNALS USING EXPONENTIAL KERNELS [J].
CHOI, HI ;
WILLIAMS, WJ .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1989, 37 (06) :862-871
[5]   TIME FREQUENCY-DISTRIBUTIONS - A REVIEW [J].
COHEN, L .
PROCEEDINGS OF THE IEEE, 1989, 77 (07) :941-981
[6]   MODERN SPECTRAL-ANALYSIS TECHNIQUES FOR BLOOD-FLOW VELOCITY AND SPECTRAL MEASUREMENTS WITH PULSED DOPPLER ULTRASOUND [J].
DAVID, JY ;
JONES, SA ;
GIDDENS, DP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (06) :589-596
[7]  
Evans D. H., 1989, DOPPLER ULTRASOUND P
[8]   EXTRACTING INSTANTANEOUS MEAN FREQUENCY INFORMATION FROM DOPPLER SIGNALS USING THE WIGNER DISTRIBUTION FUNCTION [J].
FAN, LK ;
EVANS, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (05) :429-443
[9]   NONSTATIONARITY BROADENING IN PULSED DOPPLER SPECTRUM MEASUREMENTS [J].
FISH, PJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :147-155
[10]  
FISH PJ, 1986, PHYSICAL PRINCIPLES