Mechanical conditions in the internal stabilization of proximal tibial defects

被引:46
作者
Duda, GN [1 ]
Mandruzzato, F [1 ]
Heller, M [1 ]
Kassi, JP [1 ]
Khodadadyan, C [1 ]
Haas, NP [1 ]
机构
[1] Humboldt Univ, Res Lab, Charite, D-13353 Berlin, Germany
关键词
proximal tibial defect; internal fixator; bone healing; physiological-like loading;
D O I
10.1016/S0268-0033(01)00102-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Objectives. The goal was to design a method which would permit in assessment of the suitability of a newly developed implant under physiological-like loading conditions. Information obtained from Such an analysis is expected to delineate more clearly the indications for a new device prior to clinical utilization. Design. In vitro mechanical stiffness testing and finite element analysis. Methods. From in vitro testing of proximal tibiae with defects, the stiffness of an internal stabilization system was determined. Using it finite element model, the loading of both the implant and bone was analyzed including all muscle forces. The variation in implant loading and interfragmentary strain for different defect locations was also investigated. Results. Conventional stiffness testing demonstrated the comparability of the experimental findings with the finite element predictions. Under physiological-like loading the implant experienced high bending and von Mises stresses it defects in the region of the shaft were stabilized. A short working length increased implant loading Lip to the yield strength of the material. Conclusions. The finite element analysis illustrated the appropriateness of this new device for proximal defects of the tibia, but the implant should be used hesitantly in fractures or defects extending into the diaphyseal region of the bone.
引用
收藏
页码:64 / 72
页数:9
相关论文
共 30 条
[1]
Local tissue properties in bone healing: Influence of size and stability of the osteotomy gap [J].
Augat, P ;
Margevicius, K ;
Simon, J ;
Wolf, S ;
Suger, G ;
Claes, L .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (04) :475-481
[2]
A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY [J].
BRAND, RA ;
CROWNINSHIELD, RD ;
WITTSTOCK, CE ;
PEDERSEN, DR ;
CLARK, CR ;
VANKRIEKEN, FM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :304-310
[3]
THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA [J].
BRAND, RA ;
PEDERSEN, DR ;
FRIEDERICH, JA .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :589-596
[4]
EFFECT OF DYNAMIZATION ON GAP HEALING OF DIAPHYSEAL FRACTURES UNDER EXTERNAL FIXATION [J].
CLAES, LE ;
WILKE, HJ ;
AUGAT, P ;
RUBENACKER, S ;
MARGEVICIUS, KJ .
CLINICAL BIOMECHANICS, 1995, 10 (05) :227-234
[5]
Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing [J].
Claes, LE ;
Heigele, CA .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :255-266
[6]
Influence of muscle forces on femoral strain distribution [J].
Duda, GN ;
Heller, M ;
Albinger, J ;
Schulz, O ;
Schneider, E ;
Claes, L .
JOURNAL OF BIOMECHANICS, 1998, 31 (09) :841-846
[7]
Duda GN, 2000, UNFALLCHIRURG, V103, P839, DOI 10.1007/s001130050630
[8]
Duda GN, 1998, J BIOMECH, V31, P247, DOI 10.1016/S0021-9290(97)00115-2
[9]
Mechanical boundary conditions of fracture healing: borderline indications in the treatment of unreamed tibial nailing [J].
Duda, GN ;
Mandruzzato, F ;
Heller, M ;
Goldhahn, J ;
Moser, R ;
Hehli, M ;
Claes, L ;
Haas, NP .
JOURNAL OF BIOMECHANICS, 2001, 34 (05) :639-650
[10]
Evans F. G., 1973, Mechanical Properties of Bone