Automatic on-the-fly focusing for continuous image acquisition in high-resolution microscopy

被引:11
作者
Bravo-Zanoguera, M [1 ]
von Massenbach, B [1 ]
Price, JH [1 ]
机构
[1] Univ Calif San Diego, Dept Bioengn, La Jolla, CA 92093 USA
来源
OPTICAL DIAGNOSTICS AND LIVING CELLS II, PROCEEDINGS OF | 1999年 / 3604卷
关键词
D O I
10.1117/12.349206
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
With the typically narrow depth-of-field microscope optics, biological specimens do not lie in a single focal plane across the slide and this complicates automated scanning for image cytometry. An on-the-fly autofocus system for high-resolution image cytometry is presented which keeps the image sharply focused during continuous stage travel. To track possible foci, an image volume is acquired by concurrent optical sectioning of the specimen with a dedicated imaging array. This volume scanning camera was designed for adjustment of the optical path lengths to allow simple adaptation to objectives with different depths-of-field and magnifications. The computational demand of calculating and adjusting focus dynamically is absorbed by an array of parallel autofocus circuits that measure the 3D image in real time. In conventional optical sectioning microscopy, where the image data is acquired by sequential sectioning, a priori knowledge of the specimen and its boundaries exists. In continuous volume scanning, this is usually not the case and variations in specimen thickness and information content are routine. This makes implementation of fully automatic, high-speed, high-resolution image cytometry a challenge. A model of the combined specimen and optical system was developed to evaluate strategies for tracking focus. Data from this model is described along with the volume scanning camera array design.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 14 条
[1]  
BAJAJ S, 1998, THESIS U CALIFORNIA
[2]  
BENGTSSON E, 1994, AUTOMATED CERVICAL C, P21
[3]   High-performance autofocus circuit for biological microscopy [J].
Bravo-Zanoguera, M ;
Von Massenbach, B ;
Kellner, AL ;
Price, JH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) :3966-3977
[4]  
BRAVOZANOGUERA M, 1998, SPIE, V3260, P194
[5]  
CASTLEMAN K. R., 1996, Digital image processing
[6]  
Hecht E., 1990, OPTICS
[7]   Method for evaluation of imaging in automated visual web inspection [J].
Laitinen, J ;
Moring, I .
OPTICAL ENGINEERING, 1997, 36 (08) :2184-2196
[8]  
Netten H., 1994, Bioimaging, V2, P184, DOI 10.1002/1361-6374(199412)2:4<184::AID-BIO3>3.3.CO
[9]  
2-D
[10]   COMPARISON OF PHASE-CONTRAST AND FLUORESCENCE DIGITAL AUTOFOCUS FOR SCANNING MICROSCOPY [J].
PRICE, JH ;
GOUGH, DA .
CYTOMETRY, 1994, 16 (04) :283-297