Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength

被引:87
作者
Thorborg, K. [1 ,2 ,3 ]
Bandholm, T. [2 ,3 ,4 ]
Schick, M. [1 ]
Jensen, J. [1 ]
Holmich, P. [1 ]
机构
[1] Copenhagen Univ Hosp, Arthroscop Ctr Amager, DK-2300 Copenhagen S, Denmark
[2] Copenhagen Univ Hosp, Dept Orthopaed Surg, DK-2300 Copenhagen S, Denmark
[3] Copenhagen Univ Hosp, Dept Phys Therapy, DK-2300 Copenhagen S, Denmark
[4] Copenhagen Univ Hosp, Clin Res Ctr, DK-2300 Copenhagen S, Denmark
关键词
handheld dynamometer; reproducibility; hip strength; groin; athletes; VOLUNTARY ISOMETRIC CONTRACTION; CHRONIC GROIN PAIN; MUSCLE STRENGTH; RISK-FACTORS; INTERRATER RELIABILITY; PATELLOFEMORAL PAIN; ABDUCTION STRENGTH; ANCHORING STATION; SOCCER PLAYERS; INJURIES;
D O I
10.1111/j.1600-0838.2011.01405.x
中图分类号
G8 [体育];
学科分类号
040301 [体育人文社会学];
摘要
Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty healthy individuals (29 women), aged 25 +/- 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify reliability, and ranged from 0.82 to 0.91 for the six strength test. The female tester systematically measured lower strength values for all isometric strength tests (P<0.05). In hip strength assessments using HHD, systematic bias exists between testers of different sex, which is likely explained by differences in upper-extremity strength. Hence, to improve intertester reliability, the dynamometer likely needs external fixation, as this will eliminate the influence of differences in upper-extremity strength between testers.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 34 条
[1]
TENOTOMY OF THE ADDUCTOR LONGUS TENDON IN THE TREATMENT OF CHRONIC GROIN PAIN IN ATHLETES [J].
AKERMARK, C ;
JOHANSSON, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (06) :640-643
[2]
Arokoski MH, 2002, J RHEUMATOL, V29, P2185
[3]
Beck M, 1999, MUSCLE NERVE, V22, P1265, DOI 10.1002/(SICI)1097-4598(199909)22:9<1265::AID-MUS15>3.3.CO
[4]
2-6
[5]
Hip external and internal rotation strength: Consistency over time and between sides [J].
Bohannon, Richard W. ;
Vigneault, Jeremy ;
Rizzo, Jon .
ISOKINETICS AND EXERCISE SCIENCE, 2008, 16 (02) :107-111
[6]
Bohannon RW, 1997, CLIN REHABIL, V11, P263
[7]
MAKE TESTS AND BREAK TESTS OF ELBOW FLEXOR MUSCLE STRENGTH [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1988, 68 (02) :193-194
[8]
INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY [J].
BOHANNON, RW ;
ANDREWS, AW .
PHYSICAL THERAPY, 1987, 67 (06) :931-933
[9]
TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1986, 66 (02) :206-209
[10]
Intertester reliability of hand-held dynamometry: A concise summary of published research [J].
Bohannon, RW .
PERCEPTUAL AND MOTOR SKILLS, 1999, 88 (03) :899-902