Emission image reconstruction for randoms-precorrected PET allowing negative sinogram values

被引:20
作者
Ahn, ST [1 ]
Fessler, JA [1 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
关键词
accidental coincidences; maximum-likelihood reconstruction; positron emission tomography (PET); randoms-precorrected PET;
D O I
10.1109/TMI.2004.826046
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
Most positron emission tomography (PET) emission scans are corrected for accidental coincidence (AC) events by real-time subtraction of delayed-window coincidences, leaving only the randoms-precorrected data available for image reconstruction. The real-time randoms precorrection compensates in mean for AC events but destroys the Poisson statistics. The exact log-likelihood for randoms-precorrected data is inconvenient, so practical approximations are needed for maximum likelihood or penalized-likelihood image reconstruction. Conventional approximations involve setting negative sinogram values to zero, which can induce positive systematic biases, particularly for scans with low counts per ray. We propose new likelihood approximations that allow negative sinogram values without requiring zero-thresholding. With negative sinogram values, the log-likelihood functions can be nonconcave, complicating maximization; nevertheless, we develop monotonic algorithms for the new models by modifying the separable paraboloidal surrogates and the maximum-likelihood expectation-maximization (ML-EM) methods. These algorithms ascend to local maximizers of the objective function. Analysis and simulation results show that the new shifted Poisson (SP) model is nearly free of systematic bias yet keeps low variance. Despite its simpler implementation, the new SP performs comparably to the saddle-point model which has shown the best performance (as to systematic bias and variance) in randoms-precorrected PET emission reconstruction.
引用
收藏
页码:591 / 601
页数:11
相关论文
共 46 条
[1]
Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms [J].
Ahn, S ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) :613-626
[2]
AHN S, 2003, P IEEE NUCL SCI S ME
[3]
Arfken G.B., 2013, Mathematical methods for physicists
[4]
Bertsekas D., 1999, NONLINEAR PROGRAMMIN
[5]
QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[6]
MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[7]
A MODIFIED EXPECTATION MAXIMIZATION ALGORITHM FOR PENALIZED LIKELIHOOD ESTIMATION IN EMISSION TOMOGRAPHY [J].
DEPIERRO, AR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :132-137
[8]
Ordered subsets algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2835-2851
[9]
Monotonic algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) :801-814
[10]
Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography [J].
Fessler, JA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) :493-506