Prevention of cartilage dehydration in imaging studies with a customized humidity chamber

被引:4
作者
Choo, Ryan J. [1 ]
Firminger, Colin [1 ]
Mueller, Ralph [1 ]
Stok, Kathryn S. [1 ]
机构
[1] ETH, Inst Biomech, CH-8093 Zurich, Switzerland
关键词
LASER-SCANNING MICROSCOPY; SYNCHROTRON-RADIATION; COMPUTED-TOMOGRAPHY; ARTICULAR-CARTILAGE; BONE; COLLAGEN; TISSUE;
D O I
10.1063/1.4820913
中图分类号
TH7 [仪器、仪表];
学科分类号
080401 [精密仪器及机械];
摘要
Quantitative three-dimensional imaging methods such as micro-computed tomography (mu CT) allow for the rapid and comprehensive evaluation of cartilage and bone in animal models, which can be used for drug development and related research in arthritis. However, when imaging fresh cartilage tissue in air, a common problem is tissue dehydration which causes movement artifact in the resulting images. These artifacts distort scans and can render them unusable, leading to a considerable loss of time and effort with sample preparation and measurement. The sample itself is also irretrievably damaged by the dehydration, often unable to return to its full tissue thickness upon rehydration. Additionally, imaging with ionic contrast agents such as Hexabrix (TM) must be performed in air, otherwise the agent will be washed out if immersed in a liquid. The first goal of this study was to design a customized humidity chamber to maintain cartilage hydration without the need for immersion. Following this, the use of the humidity chamber during a synchrotron radiation-mu CT scan was validated and its performance evaluated. Results showed that the loss of fluid film volume is associated with scanning at low humidity (87%), and can be avoided using the humidity chamber. Coupling this technology with advances in synchrotron imaging (e. g., phase contrast imaging) or contrast agents is promising. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:6
相关论文
共 22 条
[1]
Contrast Enhanced Computed Tomography can predict the glycosaminoglycan content and biomechanical properties of articular cartilage [J].
Bansal, P. N. ;
Joshi, N. S. ;
Entezari, V. ;
Grinstaff, M. W. ;
Snyder, B. D. .
OSTEOARTHRITIS AND CARTILAGE, 2010, 18 (02) :184-191
[2]
The effect of risedronate on bone mineralization as measured by micro-computed tomography with synchrotron radiation: Correlation to histomorphometric indices of turnover [J].
Borah, B ;
Ritman, EL ;
Dufresne, TE ;
Jorgensen, SM ;
Liu, S ;
Sacha, J ;
Phipps, RJ ;
Turner, RT .
BONE, 2005, 37 (01) :1-9
[3]
In vivo high-resolution synchrotron radiation imaging of collagen-induced arthritis in a rodent model [J].
Choi, Chang-Hyuk ;
Kim, Hong-Tae ;
Choe, Jung-Yoon ;
Kim, Seong-Kyu ;
Choi, Gi-Whan ;
Jheon, SangHoon ;
Kim, Jong-Ki .
JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 :393-399
[4]
THE ORGANIZATION OF COLLAGEN IN CRYOFRACTURED RABBIT ARTICULAR-CARTILAGE - A SCANNING ELECTRON-MICROSCOPIC STUDY [J].
CLARK, JM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (01) :17-29
[5]
Darling E., 2006, J ORTHOP RES, V22, P1182
[6]
Noninvasive Multimodal Evaluation of Bioengineered Cartilage Constructs Combining Time-Resolved Fluorescence and Ultrasound Imaging [J].
Fite, Brett Z. ;
Decaris, Martin ;
Sun, Yinghua ;
Sun, Yang ;
Lam, Adrian ;
Ho, Clark K. L. ;
Leach, J. Kent ;
Marcu, Laura .
TISSUE ENGINEERING PART C-METHODS, 2011, 17 (04) :495-504
[8]
VOLUME AND SURFACE-AREA MEASUREMENT OF VIABLE CHONDROCYTES IN-SITU USING GEOMETRIC MODELING OF SERIAL CONFOCAL SECTIONS [J].
GUILAK, F .
JOURNAL OF MICROSCOPY, 1994, 173 :245-256
[9]
Non-invasive time-lapsed monitoring and quantification of engineered bone-like tissue [J].
Hagenmueller, Henri ;
Hofmann, Sandra ;
Kohler, Thomas ;
Merkle, Hans P. ;
Kaplan, David L. ;
Vunjak-Novakovic, Gordana ;
Mueller, Ralph ;
Meinel, Lorenz .
ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (10) :1657-1667
[10]
Direct three-dimensional morphometric analysis of human cancellous bone:: Microstructural data from spine, femur, iliac crest, and calcaneus [J].
Hildebrand, T ;
Laib, A ;
Müller, R ;
Dequeker, J ;
Rüegsegger, P .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (07) :1167-1174