Arch-shaped versus flat arthrodesis of the ankle joint: strength measurements using synthetic cancellous bone

被引:10
作者
Lauge-Pedersen, H [1 ]
Aspenberg, P
Ryd, L
Tanner, KE
机构
[1] Univ Lund Hosp, Dept Orthopaed, S-22185 Lund, Sweden
[2] Univ London Queen Mary Coll, IRC Biomed Mat, London, England
[3] Linkoping Univ Hosp, Dept Orthopaed, S-58185 Linkoping, Sweden
关键词
ankle biomechanics; ankle arthrodesis; fixation; stability; strength; stiffness;
D O I
10.1243/0954411021536270
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The aim Of this Study was to see if preservation of the arch shape of the ankle at arthrodesis contributes to stability. The ankle joint was simulated by paired blocks of a synthetic material corresponding to rheumatoid cancellous bone with low stiffness and strength. Flat end constructs with and without subchondral bone were compared with arch-shape constructs with and without subchondral bone. The pairs were fixed with two screws simulating an arthrodesis. These constructs were then tested to failure in four-point bending and torque. In four-point bending the subchondral bone increased the strength, regardless of shape. Stiffness was higher in the arch-shaped specimens but was not influenced b the subchondral bone. In torque, both arch-shape and subchondral bone increase the strength. Stiffness was increased by arch-shape but not subchondral bone. The results imply that the arch-shape and subchondral bone should be preserved when performing an ankle arthrodesis, especially in weak rheumatoid bone.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 8 条
[1]
[Anonymous], 1998, FOOT, DOI DOI 10.1016/S0958-2592(98)90035-9
[2]
A BIOMECHANICAL COMPARATIVE-ANALYSIS OF 2 TECHNIQUES FOR TIBIOTALAR ARTHRODESIS [J].
FRIEDMAN, RL ;
GLISSON, RR ;
NUNLEY, JA .
FOOT & ANKLE INTERNATIONAL, 1994, 15 (06) :301-305
[3]
Miller RA, 2000, ORTHOPEDICS, V23, P457
[4]
OGILVIEHARRIS DJ, 1994, CLIN ORTHOP RELAT R, P195
[5]
SCRANTON PE, 1980, CLIN ORTHOP RELAT R, P234
[6]
ARTHRODESIS OF THE ANKLE WITH CANCELLOUS-BONE SCREWS AND FIBULAR STRUT GRAFT - BIOMECHANICAL ANALYSIS [J].
THORDARSON, DB ;
MARKOLF, KL ;
CRACCHIOLO, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (09) :1359-1363
[7]
STABILITY OF AN ANKLE ARTHRODESIS FIXED BY CANCELLOUS-BONE SCREWS COMPARED WITH THAT FIXED BY AN EXTERNAL FIXATOR - A BIOMECHANICAL STUDY [J].
THORDARSON, DB ;
MARKOLF, K ;
CRACCHIOLO, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1050-1055
[8]
TURAN I, 1995, CLIN ORTHOP RELAT R, P110