A 115 K thermo acoustically driven pulse tube refrigerator with low onset temperature

被引:20
作者
Tang, K [1 ]
Chen, GB [1 ]
Kong, B [1 ]
机构
[1] Zhejiang Univ, Cryogen Lab, Hangzhou 310027, Peoples R China
关键词
pulse tube refrigerator; thermoacoustic prime mover; thermoacoustic refrigeration;
D O I
10.1016/j.cryogenics.2003.12.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
After the modifications of jacket type water coolers and stacks, and the optimizations of the openings of orifice and double inlet valves, a refrigeration temperature as low as 115.4 K has been achieved by a thermoacoustically driven pulse tube refrigerator. By operating the double inlet valve of the pulse tube refrigerator, the onset temperature of the thermoacoustic system decreases from 550 to 340 degreesC. It provides the possibility of utilizing the low-grade heat energy. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 6 条
[1]  
[Anonymous], P I REFR LOND
[2]  
[Anonymous], 1990, Adv. Cryog. Eng.
[3]  
Chen GB, 1998, ADV CRYOG ENG, V43, P713
[4]   A thermoacoustically driven pulse tube refrigerator capable of working below 120 K [J].
Jin, T ;
Chen, GB ;
Shen, Y .
CRYOGENICS, 2001, 41 (08) :595-601
[5]  
Qiu LM, 2001, CRYOCOOLERS 11, P301
[6]   THERMOACOUSTIC ENGINES [J].
SWIFT, GW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (04) :1145-1180