The establishment of a mechanobiology model of bone and functional adaptation in response to mechanical loading

被引:13
作者
Chen, Xu-yi [2 ]
Zhang, Xi-zheng [1 ]
Guo, Yong [1 ]
Li, Rui-xin [1 ]
Lin, Jin-jin [2 ]
Wei, Yan [1 ]
机构
[1] Acad Mil Med Sci, Inst Med Equipment, Tianjin 300161, Peoples R China
[2] Chinese Peoples Army Police Force, Coll Med, Tianjin 300161, Peoples R China
基金
中国国家自然科学基金;
关键词
Mechanobiology; Strain; In vivo; Loading;
D O I
10.1016/j.clinbiomech.2008.01.016
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Background. Mechanical stimuli affected bone adaptation, however, the mechanism on a dose-response relationship between mechanical stimuli and bone response is unclear. Therefore, we established a mechanobiology model to evaluated the adaptive response of bone to strain deformation at high-frequencies (5-15 Hz) of externally applied strain. Methods. The ulnae of adult female rats were subjected to dynamic axial loading in vivo using Instron materials-testing machine. The applied loading at frequencies of 5 Hz, 10 Hz, and 15 Hz for 10 min with a haversine, low-magnitude waveform for a 2 weeks period, the peak strains is 2000 mu epsilon and 3000 mu epsilon. Strain was recorded using strain gauge conditioner and compared to physiological values obtained after testing. Findings. At frequencies of 10 Hz, 15 Hz groups, loading promoted obviously secreted of osteocalcin and collagen; a relative benefit in Bone Mineral Density (BMD) was found compare to the control (P < 0.05) followed the decline of material mechanical properties (modulus of elasticity, ultimate stress) (P < 0.01). Interpretation. These data show that a mechanobiology model of the axial ulna loading technique had been established successfully in rat. A short daily period of low-magnitude, high-frequency mechanical stimuli results in an osteogenic response related to peak strain magnitude, which do not result in significant differences in mechanical properties between the groups. Published by Elsevier Ltd.
引用
收藏
页码:S88 / S95
页数:8
相关论文
共 25 条
[1]
Nitric oxide production by bone cells is fluid shear stress rate dependent [J].
Bacabac, RG ;
Smit, TH ;
Mullender, MG ;
Dijcks, SJ ;
Van Loon, JJWA ;
Klein-Nulend, J .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2004, 315 (04) :823-829
[2]
Effects of biomechanical stress on bones in animals [J].
Burr, DB ;
Robling, AG ;
Turner, CH .
BONE, 2002, 30 (05) :781-786
[3]
Low-amplitude, broad-frequency vibration effects on cortical bone formation in mice [J].
Castillo, Alesha B. ;
Alam, Imranul ;
Tanaka, Shigeo M. ;
Levenda, Jeffery ;
li, Jiang Li ;
Warden, Stuart J. ;
Turner, Charles H. .
BONE, 2006, 39 (05) :1087-1096
[4]
Reduced mechanical load decreases the density, stiffness, and strength of cancellous bone of the mandibular condyle [J].
Giesen, EBW ;
Ding, M ;
Dalstra, M ;
van Eijden, TMGJ .
CLINICAL BIOMECHANICS, 2003, 18 (04) :358-363
[5]
Mechanical loading of diaphyseal bone in vivo: The strain threshold for an osteogenic response varies with location [J].
Hsieh, YF ;
Robling, AG ;
Ambrosius, WT ;
Burr, DB ;
Turner, CH .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (12) :2291-2297
[6]
Effects of loading frequency on mechanically induced bone formation [J].
Hsieh, YF ;
Turner, CH .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (05) :918-924
[7]
Cell mechanics and mechanotransduction: pathways, probes, and physiology [J].
Huang, HD ;
Kamm, RD ;
Lee, RT .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 2004, 287 (01) :C1-C11
[8]
HUGHESFULFORD M, 2004, SCI STKE, P12
[9]
Adaptation of bone to physiological stimuli [J].
Judex, S ;
Gross, TS ;
Bray, RC ;
Zernicke, RF .
JOURNAL OF BIOMECHANICS, 1997, 30 (05) :421-429
[10]
Proliferation of human-derived osteoblast-like cells depends on the cycle number and frequency of uniaxial strain [J].
Kaspar, D ;
Seidl, W ;
Neidlinger-Wilke, C ;
Beck, A ;
Claes, L ;
Ignatius, A .
JOURNAL OF BIOMECHANICS, 2002, 35 (07) :873-880