A new method of intraoperative hydraulic impedance measurement provides valuable prognostic information about infrainguinal graft patency

被引:9
作者
Heise, M
Krüger, U
Settmacher, U
Sklenar, S
Neuhaus, P
Scholz, H
机构
[1] Humboldt Univ, Dept Surg, D-13353 Berlin, Germany
[2] Queen Elizabeth Hosp, Dept Vasc Surg, Berlin, Germany
关键词
D O I
10.1016/S0741-5214(99)70141-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Prognostic information about graft outcome, obtained by using a new method for intraoperafive measurement of vascular impedance, was evaluated. Methods: Hydraulic impedance was measured in 136 infrainguinal bypass grafts that were entered into a multicenter trial. Seventy femoropopliteal and 66 femorocrural polytetrafluoroethylene (PTFE) grafts were used. The arterial impedance measurement involved a silicon bypass graft temporarily inserted between the proximal and distal anastomoses sites. A flowmeter probe and a pressure transducer were incorporated into the tube. The digitally stored waveforms were subjected to a fast Fourier transformation and both input (Z(x)) and characteristic (Z(0)) impedances, as well as phase relations, were computed and related to graft outcome after 3 years. Results Significant prognostic information for both popliteal and crural grafts was provided by means of the phase angle of the first harmonic. Primary and secondary patency rates for popliteal bypasses were 45% +/- 1% and 65% +/- 2% for phase angles greater than -40 degrees (n = 57) and 37% +/- 1% and 40% +/- 1% for phase angles less than -40 degrees (n = 13, (Pprim) = not significant, (Psec) < 0.01). For crural grafts, the secondary patency rates were 49% +/- 1% and 61% +/- 2% for phase angles greater than -40 degrees (n = 53) and 15% +/- 1% and 0% for phase angles less than -40 degrees (n = 13, P < .01). All crural bypass grafts with phase angles less than -40 degrees occluded within 16 months. Steady flow resistance, as well as Z(x), and Z(0), failed to indicate a significant relation to graft prognosis. Conclusion: This method provides reliable prognostic information regarding graft patency and opens hydraulic impedance measurement to clinical surgery. The phase lag between flow and pressure curves, as expressed by the phase angle of the first harmonic, provides significant prognostic information.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 32 条
[1]   INTRAOPERATIVE HEMODYNAMIC FINDINGS AND THEIR PROGNOSTIC SIGNIFICANCE IN FEMOROPOPLITEAL REVERSED SAPHENOUS-VEIN GRAFT BYPASS OPERATIONS [J].
ALBRECHTSEN, D .
SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 10 (01) :67-76
[2]  
ASCER E, 1984, J SURG RES, V37, P8, DOI 10.1016/0022-4804(84)90155-0
[3]  
ASCER E, 1984, J VASC SURG, V1, P817
[4]   INTRAOPERATIVE OUTFLOW RESISTANCE AS A PREDICTOR OF LATE PATENCY OF FEMOROPOPLITEAL AND INFRAPOPLITEAL ARTERIAL BYPASSES [J].
ASCER, E ;
VEITH, FJ ;
WHITEFLORES, SA ;
MORIN, L ;
GUPTA, SK ;
LESSER, ML .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (06) :820-827
[5]  
BUTLER PA, 1977, THESIS U SUSSEX
[6]  
Cooper G G, 1990, Eur J Vasc Surg, V4, P279, DOI 10.1016/S0950-821X(05)80208-7
[7]   INTRAOPERATIVE MEASUREMENT OF VASCULAR GRAFT RESISTANCE AS A PREDICTOR OF EARLY OUTCOME [J].
DAVIES, AH ;
MAGEE, TR ;
BAIRD, RN ;
HORROCKS, M .
BRITISH JOURNAL OF SURGERY, 1993, 80 (07) :854-857
[8]   NUMERICAL-ANALYSIS OF FLOW IN AN ELASTIC ARTERY MODEL [J].
DUTTA, A ;
WANG, DM ;
TARBELL, JM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (01) :26-33
[9]  
FARRAR DJ, 1977, CIRCULATION, V56, P171
[10]  
KARACAGIL S, 1991, SURGERY, V109, P627