Estimation of variance in single-particle reconstruction using the bootstrap technique

被引:95
作者
Penczek, PA
Yang, C
Frank, J
Spahn, CMT
机构
[1] Univ Texas, Houston Med Sch, Dept Biochem & Mol Biol, Houston, TX 77030 USA
[2] Lawrence Berkeley Natl Lab, Computat Res Div, Berkeley, CA 94720 USA
[3] Hlth Res Inc, HHMI, Wadsworth Ctr, Albany, NY 12201 USA
[4] Univ Klinikum Charite, Inst Med Phys & Biophys, Berlin, Germany
关键词
single-particle reconstruction; bootstrap; electron microscopy;
D O I
10.1016/j.jsb.2006.01.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Density maps of a molecule obtained by single-particle reconstruction from thousands of molecule projections exhibit strong changes in local definition and reproducibility, as a consequence of conformational variability of the molecule and non-stoichiometry of ligand binding. These changes complicate the interpretation of density maps in terms of molecular structure. A three-dimensional (3-D) variance map provides an effective tool to assess the structural definition in each volume element. In this work, the different contributions to the 3-D variance in a single-particle reconstruction are discussed, and an effective method for the estimation of the 3-D variance map is proposed, using a bootstrap technique of sampling. Computations with test data confirm the viability, computational efficiency, and accuracy of the method under conditions encountered in practical circumstances. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:168 / 183
页数:16
相关论文
共 59 条
[1]   Estimating alignment errors in sets of 2-D images [J].
Baldwin, PR ;
Penezek, PA .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 150 (02) :211-225
[2]   NOISE PROPERTIES OF THE EM ALGORITHM .1. THEORY [J].
BARRETT, HH ;
WILSON, DW ;
TSUI, BMW .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (05) :833-846
[3]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY - EFFECTS OF QUANTUM NOISE AND OBJECT VARIABILITY [J].
BARRETT, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (07) :1266-1278
[4]   Determination of the fold of the core protein of hepatitis B virus ky electron cryomicroscopy [J].
Bottcher, B ;
Wynne, SA ;
Crowther, RA .
NATURE, 1997, 386 (6620) :88-91
[5]   A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images [J].
Buvat, I .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10) :1761-1775
[6]   AN APPROXIMATION FORMULA FOR THE VARIANCE OF PET REGION-OF-INTEREST VALUES [J].
CARSON, RE ;
YAN, Y ;
DAUBEWITHERSPOON, ME ;
FREEDMAN, N ;
BACHARACH, SL ;
HERSCOVITCH, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :240-250
[7]   Visualization of a 4-helix bundle in the hepatitis B virus capsid by cryo-electron microscopy [J].
Conway, JF ;
Cheng, N ;
Zlotnick, A ;
Wingfield, PT ;
Stahl, SJ ;
Steven, AC .
NATURE, 1997, 386 (6620) :91-94
[8]   Estimation of image noise in PET using the bootstrap method [J].
Dahlbom, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2062-2066
[9]  
Davidson A. C., 1997, BOOTSTRAP METHODS TH
[10]   Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography [J].
Fessler, JA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) :493-506