Solid phase extraction of some metal ions on Diaion-20 resin prior to flame atomic absorption spectrometric analysis

被引:30
作者
Armagan, F
Soylak, M [1 ]
Elci, L
Dogan, M
机构
[1] Erciyes Univ, Kimya Bolumu, Fen Edebiyat Fak, TR-38039 Kayseri, Turkey
[2] Erciyes Univ, Yozgat Fen Ed Fak, Kimya Bolumu, TR-66100 Yozgat, Turkey
[3] Pamukkale Univ, Fen Edebiyat Fak, Kimya Bolumu, TR-20020 Denizli, Turkey
[4] Univ Hacettepe, Fen Fak, Kimya Bolumu, TR-06532 Ankara, Turkey
来源
JOURNAL OF TRACE AND MICROPROBE TECHNIQUES | 2002年 / 20卷 / 01期
关键词
Diaion HP-20; solid phase extraction; preconcentration; separation; trace metal ions; FAAS; Yozgat;
D O I
10.1081/TMA-120002457
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and simple method for flame atomic absorption spectrometric determination of Cu, Fe, Pb, Ni and Mn after separation/preconcentration by sorbing 8-hydroxiquinoline (OXINE) complex of analytes on the Diaion HP-20 column has been established. The metal/oxine complexes were quantitatively retained on the Diaion HP-20 at pH 9. Metals retained on the column were quantitatively (<95%) eluted with 1 M HNO3 in acetone. The accuracy of the method was demonstrated by the analysis of a stream sediment standard reference material (GBW7309) sample and by recovery on spiked samples. The method was applied to the determination of copper, iron, lead, nickel and manganese in drinking water samples and good results were obtained (Recoveries >95%, relative standard deviations <9%, relative error <3%).
引用
收藏
页码:15 / 27
页数:13
相关论文
共 32 条
[1]  
Abbu R, 2000, J TRACE MICROPROBE T, V18, P83
[2]  
Abbu R, 2000, J TRACE MICROPROBE T, V18, P15
[3]   Determination of cadmium and lead in tap water by graphite-furnace atomic absorption spectrometry after preconcentration on a finely divided ion-exchange resin as the pyrrolidinedithiocarbamate complexes [J].
Anezaki, K ;
Chen, XZ ;
Ogasawara, T ;
Nukatsuka, I ;
Ohzeki, K .
ANALYTICAL SCIENCES, 1998, 14 (03) :523-527
[4]   Electrothermal atomic absorption spectrometric determination of lead, cadmium, copper and zinc in high-salt content samples after simultaneous separation on polyethylene powder impregnated with 1-(2-pyridylazo)-2-naphthol: application to the analysis of hemodialysis fluids [J].
Bohrer, D ;
do Nascimento, PC ;
Guterres, M ;
Trevisan, M ;
Seibert, E .
ANALYST, 1999, 124 (09) :1345-1350
[5]  
Cao SX, 1999, J TRACE MICROPROBE T, V17, P157
[6]   Preconcentration and elimination of matrix effects in XRF determinations of rare earth elements by preparing a thin film through chemofiltration [J].
De Vito, IE ;
Olsina, RA ;
Masi, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :275-278
[7]   Determination of trace impurities in some nickel compounds by flame atomic absorption spectrometry after solid phase extraction using Amberlite XAD-16 resin [J].
Elçi, L ;
Soylak, M ;
Uzun, A ;
Büyükpatir, E ;
Dogan, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04) :358-361
[8]   PRECONCENTRATION OF TRACE-METALS IN RIVER WATERS BY THE APPLICATION OF CHELATE ADSORPTION ON AMBERLITE XAD-4 [J].
ELCI, L ;
SOYLAK, M ;
DOGAN, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :175-178
[9]   Determination of trace amounts of platinum by derivative spectrophotometry after column separation of palladium [J].
Godlewska-Zylkiewicz, B ;
Lesniewska, B .
JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (03) :345-354
[10]  
Hussain ST, 1998, J TRACE MICROPROBE T, V16, P139