Liquid chromatography and electron-capture dissociation in Fourier transform ion cyclotron resonance mass spectrometry

被引:52
作者
Palmblad, M
Tsybin, YO
Ramström, M
Bergquist, J
Håkansson, P
机构
[1] Uppsala Univ, Angstrom Lab, Div Ion Phys, SE-75121 Uppsala, Sweden
[2] Uppsala Univ, Dept Analyt Chem, Inst Chem, SE-75121 Uppsala, Sweden
关键词
D O I
10.1002/rcm.667
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation. The results suggest that LC/ECD-FTICRMS can be employed in the characterization of peptides in enzymatic digests of proteins or protein mixtures and identify and localize posttranslational modifications. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:988 / 992
页数:5
相关论文
共 19 条
[1]  
Axelsson J, 1999, RAPID COMMUN MASS SP, V13, P474, DOI 10.1002/(SICI)1097-0231(19990330)13:6<474::AID-RCM505>3.0.CO
[2]  
2-1
[3]   COLLISIONAL FRAGMENTATION OF GLYCOPEPTIDES BY ELECTROSPRAY IONIZATION LC MS AND LC MS MS - METHODS FOR SELECTIVE DETECTION OF GLYCOPEPTIDES IN PROTEIN DIGESTS [J].
HUDDLESTON, MJ ;
BEAN, MF ;
CARR, SA .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :877-884
[4]   CHROMATOGRAPHIC AND MASS-SPECTROMETRIC METHODS FOR THE IDENTIFICATION OF PHOSPHORYLATION SITES IN PHOSPHOPROTEINS [J].
HUNTER, AP ;
GAMES, DE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (07) :559-570
[5]   Identification of intact proteins in mixtures by alternated capillary liquid chromatography electrospray ionization and LC ESI infrared multiphoton dissociation Fourier transform ion cyclotron resonance mass spectrometry [J].
Li, WQ ;
Hendrickson, CL ;
Emmett, MR ;
Marshall, AG .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4397-4402
[6]   INFRARED MULTIPHOTON DISSOCIATION OF LARGE MULTIPLY-CHARGED IONS FOR BIOMOLECULE SEQUENCING [J].
LITTLE, DP ;
SPEIR, JP ;
SENKO, MW ;
OCONNOR, PB ;
MCLAFFERTY, FW .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2809-2815
[7]   ERROR TOLERANT IDENTIFICATION OF PEPTIDES IN SEQUENCE DATABASES BY PEPTIDE SEQUENCE TAGS [J].
MANN, M ;
WILM, M .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4390-4399
[8]   USE OF MASS-SPECTROMETRIC MOLECULAR-WEIGHT INFORMATION TO IDENTIFY PROTEINS IN SEQUENCE DATABASES [J].
MANN, M ;
HOJRUP, P ;
ROEPSTORFF, P .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (06) :338-345
[9]  
MEIER J, COMMUNICATION
[10]   Localization of O-glycosylation sites in peptides by electron capture dissociation in a fourier transform mass spectrometer [J].
Mirgorodskaya, E ;
Roepstorff, P ;
Zubarev, RA .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4431-4436