Improving the analytical performance of hydride generation non-dispersive atomic fluorescence spectrometry. Combined effect of additives and optical filters

被引:41
作者
D'Ulivo, A
Bramanti, E
Lampugnani, L
Zamboni, R
机构
[1] Natl Res Council Italy, Inst Instrumental Anal Chem, Res Area Pisa, I-56124 Pisa, Italy
[2] Univ Pisa, Dept Chem & Ind Chem, I-56126 Pisa, Italy
关键词
hydride generation atomic fluorescence spectrometry; interference control; L-cysteine; thiourea; iodide; optical filter;
D O I
10.1016/S0584-8547(01)00341-X
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The effects of tetrahydroborate and acid concentration and the presence Of L-cysteine and thiourea were investigated in the determination of As, Bi and Sn using continuous flow hydride generation atomic fluorescence spectrometry (HG AFS). The aim was to find conditions allowing the control of those effects exerting negative influence on the analytical performance of the HG AFS apparatus. The effects taken into account were: (i) the radiation scattering generated by carryover of solution from the gas-liquid separator to the atomizer; GO the introduction of molecular species generated by tetrahydroborate decomposition into the atomizer; and (iii) interference effects arising from other elements in the sample matrix and from different acids. The effects (i) and (ii) could be controlled using mild reaction conditions in the HG stage. The effect of FIG conditions on carryover was studied by radiation scattering experiments without hydride atomization. Compromised HG conditions were found by studying the effects of tetrahydroborate (0.1-20 g l(-1)) and acid (0.01-7 mol l(-1)) concentration, and the addition of L-cysteine (10 g l(-1)) and thiourea (0.1, mol l(-1)) on the HG AFS signals. The effect of optical filters was investigated with the aim of improving the signal-to-noise ratio. Optical filters with peak wavelengths of 190 and 220 nm provided an improvement of detection limits by factors of approximately 4 and 2 for As and Te, respectively. Under optimized conditions the detection limits were 6, 5, 3, 2, 2 and 9 ng l(-1) for As, Sb, Bi, Sn, Se and Te, respectively. Good tolerance to various acid compositions and sample matrices was obtained by using L-cysteine or thiourea as masking agents. Determination of arsenic in sediment and copper certified reference materials, and of bismuth in steel, sediment, soil and ore certified reference material is reported. (9) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1893 / 1907
页数:15
相关论文
共 26 条
[1]   A STUDY ON THE GENERATION OF HYDROGEN SELENIDE AND DECOMPOSITION OF TETRAHYDROBORATE IN HYDRIDE-GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
AGTERDENBOS, J ;
BAX, D .
ANALYTICA CHIMICA ACTA, 1986, 188 :127-135
[2]   Interferences in the quartz tube atomizer during arsenic and antimony determination by hydride generation atomic absorption spectrometry [J].
Ay, Ü ;
Henden, E .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :951-958
[3]   Cold vapour atomic fluorescence studies on the behaviour of mercury(II) and mercury(II)-thiol complexes. An alternative route for characterization of -SH binding groups [J].
Bramanti, E ;
D'Ulivo, A ;
Lampugnani, L ;
Raspi, G ;
Zamboni, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (02) :179-185
[4]  
BRAMANTI E, 1997, 30 C SPECTR INT 21 2, P71
[5]   DETERMINATION OF TIN BY ATOMIC FLUORESCENCE SPECTROSCOPY, WITH AN ELECTRONICALLY MODULATED ELECTRODELESS DISCHARGE TUBE AS SOURCE [J].
BROWNER, RF ;
DAGNALL, RM ;
WEST, TS .
ANALYTICA CHIMICA ACTA, 1969, 46 (02) :207-&
[6]   PREREDUCTION OF ARSENIC(V) TO ARSENIC(III), ENHANCEMENT OF THE SIGNAL, AND REDUCTION OF INTERFERENCES BY L-CYSTEINE IN THE DETERMINATION OF ARSENIC BY HYDRIDE GENERATION [J].
CHEN, HW ;
BRINDLE, ID ;
LE, XC .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :667-672
[7]   Studies in hydride generation atomic fluorescence determination of selenium and tellurium. Part 1 - self interference effect in hydrogen telluride generation and the effect of KI [J].
D'Ulivo, A ;
Marcucci, K ;
Bramanti, E ;
Lampugnani, L ;
Zamboni, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (08) :1325-1336
[8]   STUDIES IN ATOMIC-FLUORESCENCE SPECTROSCOPY .6. FLUORESCENCE CHARACTERISTICS AND ANALYTICAL DETERMINATION OF BISMUTH WITH AN IODINE ELECTRODELESS DISCHARGE TUBE AS SOURCE [J].
DAGNALL, RM ;
THOMPSON, KC ;
WEST, TS .
TALANTA, 1967, 14 (12) :1467-&
[9]   STUDIES IN ATOMIC-FLUORESCENCE SPECTROSCOPY .4. ATOMIC-FLUORESCENCE SPECTROSCOPIC DETERMINATION OF SELENIUM AND TELLURIUM [J].
DAGNALL, RM ;
THOMPSON, KC ;
WEST, TS .
TALANTA, 1967, 14 (05) :557-&
[10]   Argon shielded, highly fuel-rich, hydrogen-oxygen diffusion microflame - a new hydride atomizer [J].
Dedina, J ;
D'Ulivo, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1737-1746