Reliability of computer designed surgical guides in six implant rehabilitations with two years follow-up

被引:26
作者
Giordano, Mauro [2 ]
Ausiello, Pietro [3 ]
Martorelli, Massimo [1 ]
Sorrentino, Roberto [3 ]
机构
[1] Univ Naples Federico II, Sch Engn, Dept Mech & Energet DiME, I-80125 Naples, Italy
[2] Giordano Dent Off, Caserta, Italy
[3] Univ Naples Federico II, Sch Dent, Dept Restorat Dent, I-80131 Naples, Italy
关键词
Surgical guides; Virtual modeling; Osseointegration; Minimally invasive approach; Muco-compressive impression; Muco-static impression; LEAST; 5; YEARS; COMPLICATION RATES; OBSERVATION PERIOD; CANTILEVER; SURVIVAL; DENTURES; SURGERY;
D O I
10.1016/j.dental.2012.06.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To evaluate the reliability and accuracy of computer-designed surgical guides in osseointegrated oral implant rehabilitation. Materials and methods. Six implant rehabilitations, with a total of 17 implants, were completed with computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. In the first case, the surgical guide had exclusively mucosal support, in the second case exclusively dental support. For all six cases computer-aided surgical planning was performed by virtual analyses with 3D models obtained by dental scan DICOM data. The accuracy and stability of implant osseointegration over two years post surgery was then evaluated with clinical and radiographic examinations. Radiographic examination, performed with digital acquisitions (RVG - Radio Video graph) and parallel techniques, allowed two-dimensional feedback with a margin of linear error of 10%. Results. Implant osseointegration was recorded for all the examined rehabilitations. During the clinical and radiographic post-surgical assessments, over the following two years, the peri-implant bone level was found to be stable and without appearance of any complications. The margin of error recorded between pre-operative positions assigned by virtual analysis and the post-surgical digital radiographic observations was as low as 0.2 mm. Significance. Computer-guided implant surgery can be very effective in oral rehabilitations, providing an opportunity for the surgeon: (a) to avoid the necessity of muco-periosteal detachments and then (b) to perform minimally invasive interventions, whenever appropriate, with a flapless approach. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E168 / E177
页数:10
相关论文
共 21 条
[1]  
Aglietta M, 2005, INT J ORAL MAXILLOF, V20, P416
[2]   A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years [J].
Aglietta, Marco ;
Siciliano, Vincenzo Iorio ;
Zwahlen, Marcel ;
Braegger, Urs ;
Pjetursson, Biarni E. ;
Lang, Niklaus P. ;
Salvi, Giovanni E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) :441-451
[3]   Mechanical behavior of post-restored upper canine teeth: A 3D FE analysis [J].
Ausiello, Pietro ;
Franciosa, Pasquale ;
Martorelli, Massimo ;
Watts, David C. .
DENTAL MATERIALS, 2011, 27 (12) :1285-1294
[4]   Numerical fatigue 3D-FE modeling of indirect composite-restored posterior teeth [J].
Ausiello, Pietro ;
Franciosa, Pasquale ;
Martorelli, Massimo ;
Watts, David C. .
DENTAL MATERIALS, 2011, 27 (05) :423-430
[5]   THE INFLUENCE OF CANTILEVER LENGTH AND IMPLANT INCLINATION ON STRESS DISTRIBUTION IN MAXILLARY IMPLANT-SUPPORTED FIXED DENTURES [J].
Bevilacqua, Marco ;
Tealdo, Tiziano ;
Menini, Maria ;
Pera, Francesco ;
Mossolov, Alexei ;
Drago, Carl ;
Pera, Paolo .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (01) :5-13
[6]  
Bianco J, 2012, CLIN ORAL IMPLAN RES, V23, P70
[7]  
Bianco J, 2010, J CLIN PERIODONTOL, V37, P937
[8]   Radiographic evaluation of mandibular posterior implant sites: Correlation between panoramic and tomographic determinations [J].
Bolin, A ;
Eliasson, S ;
vonBeetzen, M ;
Jansson, L .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (04) :354-359
[9]   Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate [J].
Gahleitner, A ;
Podesser, B ;
Schick, S ;
Watzek, G ;
Imhof, H .
EUROPEAN JOURNAL OF RADIOLOGY, 2004, 51 (03) :257-262
[10]  
Garg A K, 1995, Implant Soc, V5, P7