An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams

被引:20
作者
Mobit, PN
Sandison, GA
机构
[1] Tom Baker Canc Clin, Dept Med Phys, Calgary, AB T2N 4N2, Canada
[2] Univ Calgary, Dept Radiat Oncol, Calgary, AB T2N 4N2, Canada
关键词
Monte Carlo; perturbation; diamond detector;
D O I
10.1118/1.598593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irradiation was simulated at various depths in a water phantom. The results show that the PTW/diamond detector has a constant response (within 1.0%) in electron beams if irradiated at depths closed to d(max), and its response is almost independent of irradiation depth or incident electron energy (within 3%). A detailed examination of the average detector dose shows that the sensitive volume of the PTW/diamond detector acts as a Spencer-Attix cavity within 1%. The encapsulation of the bare diamond detector with low-Z epoxy and polystyrene wall material does not affect its response in electron beams. The difference in response between the unencapsulated (TLD) and the encapsulated form of the detector is less than 0.5% for all depths over electron energy range investigated. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00605-7].
引用
收藏
页码:839 / 844
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 1983, MED PHYS, V10, P741
[2]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[3]  
Duane S., 1989, PIRS0173 NRCC PIRS0173 NRCC
[4]   EVALUATION OF A PTW DIAMOND DETECTOR FOR ELECTRON-BEAM MEASUREMENTS [J].
HEYDARIAN, M ;
HOBAN, PW ;
BECKHAM, WA ;
BORCHARDT, IM ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (08) :1035-1042
[5]  
*INT AT EN AG, 1987, TECHN REP SER INT AT, V277
[6]  
International Commission in Radiation Units and Measurements, 1984, 37 ICRU
[7]   THE DETECTION OF IONIZING-RADIATIONS BY NATURAL AND SYNTHETIC DIAMOND CRYSTALS AND THEIR APPLICATION AS DOSIMETERS IN BIOLOGICAL ENVIRONMENTS [J].
KEDDY, RJ ;
NAM, TL ;
BURNS, RC .
CARBON, 1988, 26 (03) :345-356
[8]  
KHRUNOV VS, 1990, RADIAT PROT DOSIM, V33, P155
[9]   CALCULATION OF ABSORBED DOSE RATIOS USING CORRELATED MONTE-CARLO SAMPLING [J].
MA, CM ;
NAHUM, AE .
MEDICAL PHYSICS, 1993, 20 (04) :1189-1199
[10]  
MA CM, 1992, THESIS U LONDON