Determination of trunk muscle forces for flexion and extension by using a validated finite element model of the lumbar spine and measured in vivo data

被引:154
作者
Rohlmann, A [1 ]
Bauer, L [1 ]
Zander, T [1 ]
Bergmann, G [1 ]
Wilke, HJ [1 ]
机构
[1] Charite, Biomech Lab, D-12203 Berlin, Germany
关键词
lumbar spine; muscle forces; finite element method; posture;
D O I
10.1016/j.jbiomech.2005.02.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Muscle forces stabilize the spine and have a great influence on spinal loads. But little is known about their magnitude. In a former in vitro experiment, a good agreement with intradiscal pressure and fixator loads measured in vivo could be achieved for standing and extension of the lumbar spine. However, for flexion the agreement between in vitro and in vivo measurements was insufficient. In order to improve the determination of trunk muscle forces, a three-dimensional nonlinear finite element model of the lumbar spine with an internal fixation device was created and the same loads were applied as in a previous in vitro experiment. An extensive adaptation process of the model was performed for flexion and extension angles up to 20 degrees and -15 degrees, respectively. With this validated computer model intra-abdominal pressure, preload in the fixators, and a combination of hip- and lumbar flexion angle were varied until a good agreement between analytical and in vivo results was reached for both, intradiscal pressure and bending moments in the fixators. Finally, the fixators were removed and the muscle forces for the intact lumbar spine calculated. A good agreement with the in vivo results could only be achieved at a combination of hip- and lumbar flexion. For the intact spine, forces of 170, 100 and 600 N are predicted in the m. erector spinae for standing, 5 degrees extension and 30 degrees flexion, respectively. The force in the m. rectus abdominus for these body positions is less than 25 N. For more than 10 degrees extension the in. erector spinae is unloaded. The finite element method together with in vivo data allows the estimation of trunk muscle forces for different upper body positions in the sagittal plane. In our patients, flexion of the upper body was most likely a combination of hip- and lumbar spine bending. (c) 2005 Published by Elsevier Ltd.
引用
收藏
页码:981 / 989
页数:9
相关论文
共 30 条
[1]
Bergmark A, 1989, Acta Orthop Scand Suppl, V230, P1
[2]
A UNIVERSAL MODEL OF THE LUMBAR BACK MUSCLES IN THE UPRIGHT POSITION [J].
BOGDUK, N ;
MACINTOSH, JE ;
PEARCY, MJ .
SPINE, 1992, 17 (08) :897-913
[3]
Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices [J].
Calisse, J ;
Rohlmann, A ;
Bergmann, G .
JOURNAL OF BIOMECHANICS, 1999, 32 (07) :727-731
[4]
THE INTERSEGMENTAL AND MULTISEGMENTAL MUSCLES OF THE LUMBAR SPINE - A BIOMECHANICAL MODEL COMPARING LATERAL STABILIZING POTENTIAL [J].
CRISCO, JJ ;
PANJABI, MM .
SPINE, 1991, 16 (07) :793-799
[5]
THE RELATIONSHIP BETWEEN EMG ACTIVITY AND EXTENSOR MOMENT GENERATION IN THE ERECTOR SPINAE MUSCLES DURING BENDING AND LIFTING ACTIVITIES [J].
DOLAN, P ;
ADAMS, MA .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :513-522
[6]
CANCELLOUS BONE YOUNGS MODULUS VARIATION WITHIN THE VERTEBRAL BODY OF A LIGAMENTOUS LUMBAR SPINE - APPLICATION OF BONE ADAPTIVE REMODELING CONCEPTS [J].
GOEL, VK ;
RAMIREZ, SA ;
KONG, WZ ;
GILBERTSON, LG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03) :266-271
[7]
INTERLAMINAR SHEAR STRESSES AND LAMINAE SEPARATION IN A DISC - FINITE-ELEMENT ANALYSIS OF THE L3-L4 MOTION SEGMENT SUBJECTED TO AXIAL COMPRESSIVE LOADS [J].
GOEL, VK ;
MONROE, BT ;
GILBERTSON, LG ;
BRINCKMANN, P ;
NAT, R .
SPINE, 1995, 20 (06) :689-698
[8]
A biomechanical model of the lumbar spine during upright isometric flexion, extension, and lateral bending [J].
Guzik, DC ;
Keller, TS ;
Szpalski, M ;
Park, JH ;
Spengler, DM .
SPINE, 1996, 21 (04) :427-433
[9]
THE EFFECTS OF FLEXION ON THE GEOMETRY AND ACTIONS OF THE LUMBAR ERECTOR SPINAE [J].
MACINTOSH, JE ;
BOGDUK, N ;
PEARCY, MJ .
SPINE, 1993, 18 (07) :884-893
[10]
Intra-abdominal pressure during trunk extension motions [J].
Marras, WS ;
Mirka, GA .
CLINICAL BIOMECHANICS, 1996, 11 (05) :267-274