Use of CT-Based Intraoperative Spinal Navigation: Management of Radiation Exposure to Operator, Staff, and Patients

被引:51
作者
Bandela, John R. [1 ]
Jacob, R. Patrick [1 ]
Arreola, Manuel [2 ]
Griglock, Thomas M. [2 ]
Bova, Frank [1 ]
Yang, Mu [1 ]
机构
[1] Univ Florida, Dept Neurosurg, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Radiol, Gainesville, FL 32610 USA
关键词
Cone-beam computed tomography; Radiation; Stereotaxic techniques; PEDICLE SCREW INSERTION; ASSISTED SURGICAL TREATMENTS; IMAGE GUIDANCE; PLACEMENT; FLUOROSCOPY; SURGERY; DISORDERS; ACCURACY; RISKS;
D O I
10.1016/j.wneu.2011.05.019
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
OBJECTIVE: Radiation exposure represents significant risk to both operating room health care workers and their patients. The commonplace surgical implantation of spinal instrumentation often relies on fluoroscopy for guidance and Verification. Advances in computerized tomography (CT)-based intraoperative navigation have improved accuracy of screw placement. The objective of this article is to quantify the radiation exposure from fluoroscopic and CT-based intraoperative navigation and to provide guidance in mitigating the exposure to patient and operating room (OR) staff. METHODS: With radiation measurement devices in place, a female cadaver underwent pedicle screws from T7 to S1. The left side was guided by fluoroscopy, the right side by CT-based navigation. In addition, a CT-based navigation system was placed in an empty OR. Measurements of radiation while scanning phantom were undertaken at various positions around the OR. RESULTS: The use of intraoperative CT-based navigation virtually eliminated radiation exposure to the surgeon. However, the radiation dose to the patient was increased compared with fluoroscopy. In addition, the radiation profile of the CT-based navigation system was not uniform with significantly lower radiation perpendicular to the axis of the patient on the side of the control panel. CONCLUSIONS: Use of intraoperative CT-based navigation systems results in lower radiation dose to the surgeon compared with fluoroscopic-based methods. There is an increase in the radiation to the patient. In addition, it is necessary to consider and eliminate other perioperative sources of radiation, such as a postoperative CT scan, which are made redundant by this technology.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 20 条
[1]
[Anonymous], 2010, MEDTRONIC O ARM SYST, V2010
[2]
[Anonymous], 2006, BEIR 7 PHASE 2 HLTH, DOI 10.17226/11340
[3]
Battaglia Todd C, 2005, J Surg Orthop Adv, V14, P175
[4]
BEIR VII, 2005, BEIR 7 HLTH RISKS EX
[5]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]
Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: Is fluoroscopy safe? [J].
Haque, Maahir Ul ;
Shufflebarger, Harry L. ;
O'Brien, Michael ;
Macagno, Angel .
SPINE, 2006, 31 (21) :2516-2520
[7]
Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery [J].
Kim, Choll W. ;
Lee, Yu-Po ;
Taylor, William ;
Oygar, Ahmet ;
Kim, Woo Kyung .
SPINE JOURNAL, 2008, 8 (04) :584-590
[8]
Free hand pedicle screw placement in the thoracic spine: Is it safe? [J].
Kim, YJ ;
Lenke, LG ;
Bridwell, KH ;
Cho, YSS ;
Riew, KD .
SPINE, 2004, 29 (03) :333-342
[9]
Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance - A cadaver study [J].
Mirza, SK ;
Wiggins, GC ;
Kuntz, C ;
York, JE ;
Bellabarba, C ;
Knonodi, MA ;
Chapman, JR ;
Shaffrey, CI .
SPINE, 2003, 28 (04) :402-413
[10]
Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort Clinical article [J].
Nottmeier, Eric W. ;
Seemer, Will ;
Young, Phillip M. .
JOURNAL OF NEUROSURGERY-SPINE, 2009, 10 (01) :33-39