Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis

被引:45
作者
Hirschmann, Michael T. [1 ]
Wagner, Christopher R. [2 ]
Rasch, Helmut [3 ]
Henckel, Johann [4 ]
机构
[1] Kantonsspital Bruderholz, Dept Orthopaed Surg & Traumatol, CH-4101 Bruderholz, Switzerland
[2] OrthoImagingSolut Ltd, London, England
[3] Kantonsspital Bruderholz, Inst Radiol & Nucl Med, CH-4101 Bruderholz, Switzerland
[4] Univ London Imperial Coll Sci Technol & Med, Dept Musculoskeletal Surg, London, England
关键词
TOMOGRAPHY; UTILITY; SYSTEM; CT;
D O I
10.1186/1471-2342-12-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Background: SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions. Methods: We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity. Results: Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology. Conclusions: Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool.
引用
收藏
页数:10
相关论文
共 23 条
[1]
Utility of SPECT/CT as an Adjunct to Planar Whole Body I-131 Imaging [J].
Agriantonis, Demetrios J. ;
Hall, Lance ;
Wilson, Michael A. .
CLINICAL NUCLEAR MEDICINE, 2009, 34 (04) :247-248
[2]
Complementary roles of low-dose SPECT-CT and high-resolution volume CT for detection of coronary artery disease [J].
Akincioglu, Cigdem ;
Belhocine, Tarik ;
Gambhir, Sanjay ;
Romsa, Jonathan ;
Chouraiki, Ghita ;
Kribs, Stewart ;
Elliot, James A. ;
Vezina, William ;
Urbain, Jean-Luc .
CLINICAL NUCLEAR MEDICINE, 2008, 33 (04) :285-287
[3]
Bernstein MP, 2000, J NUCL MED, V41, P1075
[4]
Quantitative Radionuclide Studies of Bone [J].
Blake, Glen M. ;
Frost, Michelle L. ;
Fogelman, Ignac .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (11) :1747-1750
[5]
Quantitative Studies of Bone Using 99mTc-Methylene Diphosphonate Skeletal Plasma Clearance [J].
Blake, Glen M. ;
Moore, Amelia E. B. ;
Fogelman, Ignac .
SEMINARS IN NUCLEAR MEDICINE, 2009, 39 (06) :369-379
[6]
Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images [J].
Bocher, M ;
Balan, A ;
Krausz, Y ;
Shrem, Y ;
Lonn, A ;
Wilk, M ;
Chisin, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (06) :619-627
[7]
SPECT/CT imaging: Clinical utility of an emerging technology [J].
Bybel, Bohdan ;
Brunken, Richard C. ;
DiFilippo, Frank P. ;
Neumann, Donald R. ;
Wu, Guiyun ;
Cerqueira, Manuel D. .
RADIOGRAPHICS, 2008, 28 (04) :1097-1113
[8]
Hybrid Imaging (SPECT/CT and PET/CT)-Improving the Diagnostic Accuracy of Functional/Metabolic and Anatomic Imaging [J].
Even-Sapir, Einat ;
Keidar, Zohar ;
Bar-Shalom, Rachel .
SEMINARS IN NUCLEAR MEDICINE, 2009, 39 (04) :264-275
[9]
123I-FP-CIT semi-quantitative SPECT detects preclinical bilateral doparninergic deficit in early Parkinson's disease with unilateral symptoms [J].
Filippi, L ;
Manni, C ;
Pierantozzi, M ;
Brusa, L ;
Danieli, R ;
Stanzione, P ;
Schillaci, D .
NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (05) :421-426
[10]
Very low-dose computed tomography for planning and outcome measurement in knee replacement - The imperial knee protocol [J].
Henckel, J. ;
Richards, R. ;
Lozhkin, K. ;
Harris, S. ;
Rodriguez y Baena, F. M. ;
Barrett, A. R. W. ;
Cobb, J. P. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (11) :1513-1518