Progress with saturated soft X-ray lasers pumped by the Vulcan laser

被引:14
作者
Lewis, CLS [1 ]
Keenan, R [1 ]
MacPhee, AG [1 ]
Moore, B [1 ]
O'Rourke, RMN [1 ]
Tallents, GJ [1 ]
Dobosz, S [1 ]
Peschete, J [1 ]
Strati, F [1 ]
Wark, JS [1 ]
Wolfrum, E [1 ]
Pert, GJ [1 ]
MacCabe, SP [1 ]
Simms, PA [1 ]
Allott, R [1 ]
Collier, J [1 ]
Danson, CN [1 ]
Djaoui, A [1 ]
Neely, D [1 ]
机构
[1] Queens Univ Belfast, Sch Math & Phys, Belfast BT7 1NN, Antrim, North Ireland
来源
SOFT X-RAY LASERS AND APPLICATIONS III | 1999年 / 3776卷
关键词
x-ray laser; travelling wave; non-linear optics;
D O I
10.1117/12.366679
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Ne-like and Ni-like ions have been pumped in the transient gain regime using intense picosecond pump pulses from Vulcan in its CPA mode. High gain coefficients of at least similar to 30/cm are observed for the Ne-like ions Ti XIII, Ge XXIII and Sn XXIII at wavelengths 31.2, 19.6 and 12.0 nm respectively and similar to 20/cm for the Ni-like ion Sm XXXV at 7.3 nm. Saturated output is found in all cases for target lengths shorter than 10 mm and the effect of travelling wave pumping has been studied and unequivocably demonstrated. An experimental campaign to observe four wave mixing using a soft x-ray laser and an optical laser in a sum-difference frequency mixing (SDFM) scheme has been initiated. Preliminary results are described and future directions discussed.
引用
收藏
页码:292 / 301
页数:10
相关论文
共 27 条
[1]  
Afanas'ev Yu. V., 1989, Soviet Journal of Quantum Electronics, V19, P1606, DOI 10.1070/QE1989v019n12ABEH009835
[2]   EFFICIENT SOFT-X-RAY LASING AT 6 TO 8 NM WITH NICKEL-LIKE LANTHANIDE IONS [J].
DAIDO, H ;
KATO, Y ;
MURAI, K ;
NINOMIYA, S ;
KODAMA, R ;
YUAN, G ;
OSHIKANE, Y ;
TAKAGI, M ;
TAKABE, H ;
KOIKE, F .
PHYSICAL REVIEW LETTERS, 1995, 75 (06) :1074-1077
[3]   Demonstration of x-ray amplification in transient gain nickel-like palladium scheme [J].
Dunn, J ;
Osterheld, AL ;
Shepherd, R ;
White, WE ;
Shlyaptsev, VN ;
Stewart, RE .
PHYSICAL REVIEW LETTERS, 1998, 80 (13) :2825-2828
[4]   Transient high gains at 196 angstrom produced by picosecond pulse heating of a preformed germanium plasma [J].
Healy, SB ;
Janulewicz, KA ;
Plowes, JA ;
Pert, GJ .
OPTICS COMMUNICATIONS, 1996, 132 (5-6) :442-448
[5]   A COMPUTATIONAL INVESTIGATION OF THE NEON-LIKE GERMANIUM COLLISIONALLY-PUMPED LASER CONSIDERING THE EFFECT OF PREPULSES [J].
HEALY, SB ;
CAIRNS, GF ;
LEWIS, CLS ;
PERT, GJ ;
PLOWES, JA .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1995, 1 (03) :949-957
[6]   Saturated operation of a transient collisional x-ray laser [J].
Kalachnikov, MP ;
Nickles, PV ;
Schnurer, M ;
Sandner, W ;
Shlyaptsev, VN ;
Danson, C ;
Neely, D ;
Wolfrum, E ;
Zhang, J ;
Behjat, A ;
Demir, A ;
Tallents, GJ ;
Warwick, PJ ;
Lewis, CLS .
PHYSICAL REVIEW A, 1998, 57 (06) :4778-4783
[7]  
Klisnick A, 1999, INST PHYS CONF SER, V159, P107
[8]   Temporally and spatially resolved investigation of the J=0-1 and J=2-1, 3p-3s laser emissions in neonlike germanium [J].
Li, YL ;
Pretzler, G ;
Fill, EE ;
Nilsen, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1996, 13 (04) :742-750
[9]   Optimization of double pulse pumping for Ni-like Sm x-ray lasers [J].
Lin, JY ;
Tallents, GJ ;
Smith, R ;
MacPhee, AG ;
Wolfrum, E ;
Zhang, J ;
Eker, G ;
Keenan, R ;
Lewis, CLS ;
Neely, D ;
O'Rourke, RMN ;
Pert, GJ ;
Pestehe, SJ ;
Wark, JS .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) :672-675
[10]  
MacPhee AG, 1999, INST PHYS CONF SER, V159, P75