Improving preanalytic processes using the principles of lean production (Toyota Production System)

被引:51
作者
Persoon, TJ
Zaleski, S
Frerichs, J
机构
[1] Univ Iowa, Dept Pathol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Mech & Ind Engn, Iowa City, IA 52242 USA
关键词
preanalytic; process improvement; lean production; turnaround time;
D O I
10.1309/865V7UMFPUKGCF8D
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The basic technologies used in preanalytic processes for chemistry tests have been mature for a long time, and improvements in preanalytic processes have lagged behind improvements in analytic and postanalytic processes. We describe our successful efforts to improve chemistry test turnaround time from a central laboratory by improving preanalytic processes, using existing resources and the principles of lean production. Our goal is to report 80% of chemistry tests in less than 1 hour and to no longer recognize a distinction between expedited and routine testing. We used principles of lean production (the Toyota Production System) to redesign preanalytic processes. The redesigned preanalytic process has fewer steps and uses 1-piece flow to move blood samples through the accessioning, centrifugation, and aliquoting processes. Median preanalytic processing time was reduced from 29 to 19 minutes, and the laboratory met the goal of reporting 80% of chemistry results in less than 1 hour for 11 consecutive months.
引用
收藏
页码:16 / 25
页数:10
相关论文
共 10 条
[1]  
Bahensky James A, 2005, J Healthc Inf Manag, V19, P39
[2]   Error-free pathology: applying lean production methods to anatomic pathology [J].
Condel, JL ;
Sharbaugh, DT ;
Raab, SS .
CLINICS IN LABORATORY MEDICINE, 2004, 24 (04) :865-+
[3]   Timeliness as a quality attribute and strategy [J].
Howanitz, JH ;
Howanitz, PJ .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2001, 116 (03) :311-315
[4]   Reducing Waste and Errors: Piloting Lean Principles at Intermountain Healthcare [J].
Jimmerson, Cindy ;
Weber, Dorothy ;
Sobek, Durward K., II .
JOINT COMMISSION JOURNAL ON QUALITY AND PATIENT SAFETY, 2005, 31 (05) :249-257
[5]   Medical errors: An introduction to concepts [J].
Kalra, J .
CLINICAL BIOCHEMISTRY, 2004, 37 (12) :1043-1051
[6]   Use of computer simulation to study impact of increasing routine test volume on turnaround times of STAT samples on ci8200 integrated chemistry and immunoassay analyzer [J].
Mohammad, AA ;
Elefano, EC ;
Leigh, D ;
Stredler, D ;
Okorodudu, AO ;
Petersen, JR .
CLINICAL CHEMISTRY, 2004, 50 (10) :1952-1955
[7]  
Ohno T., 1998, TOYOTA PRODUCTION SY
[8]  
Spear S, 1999, HARVARD BUS REV, V77, P96
[9]   Driving improvement in patient care - Lessons from Toyota [J].
Thompson, DN ;
Wolf, GA ;
Spear, SJ .
JOURNAL OF NURSING ADMINISTRATION, 2003, 33 (11) :585-595
[10]   Curing a meagre health care system by lean methods -: translating 'chains of care' in the Swedish health care sector [J].
Trägårdh, B ;
Lindberg, K .
INTERNATIONAL JOURNAL OF HEALTH PLANNING AND MANAGEMENT, 2004, 19 (04) :383-398