Secondary X-ray imaging: an alternative approach to angiography and other applications

被引:5
作者
Csonka, PL [1 ]
机构
[1] Univ Oregon, Inst Theoret Sci, Eugene, OR 97403 USA
关键词
X-ray imaging; angiography; wigglers; K-edge subtraction;
D O I
10.1016/S0168-9002(99)00260-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Secondary X-ray imaging is made possible by the energetic X-ray beams emerging from wigglers,. or preferably undulators, installed on electron storage rings. It is applicable to microtomographic studies of complex samples, and medical imaging. As an alternative, or complement to the elegant KES and DPA-based imaging techniques, it offers the advantages of broad frequency band acceptance, the decoupling of primary and secondary X-ray energies, thereby reducing the absorbtion of the former by the human body;and avoids the need for monochromatization. These factors contribute to reducing the primary photon intensity required for the same image quality. Also, with this method sharp image quality is compatible with locally quantitative measurements, and (depending on the detector) with a pixel by pixel elemental analysis. Drawbacks are: the beam is to be rastered through the sample along both x and y, the detector area has to be large, timing of secondary photons has to be recorded, and primary photon reflectors must operate at grazing incidence angles. As an example human angiography is considered. It is found that both the APS and PETRA. II machines can produce significantly more photons than is required for high-quality medical imaging. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:306 / 319
页数:14
相关论文
共 22 条
[1]  
ARTHUR JR, COMMUNICATION
[2]   TESTS OF VARIABLE-BAND MULTILAYERS DESIGNED FOR INVESTIGATING OPTIMAL SIGNAL-TO-NOISE VERSUS ARTIFACT SIGNAL RATIOS IN DUAL-ENERGY DIGITAL SUBTRACTION ANGIOGRAPHY (DDSA) IMAGING-SYSTEMS [J].
BOYERS, D ;
HO, A ;
LI, Q ;
PIESTRUP, M ;
RICE, M ;
TATCHYN, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (03) :565-570
[3]  
CREMER T, XREFLECTION NEW GRAP
[5]  
CSONKA PL, 1992, WORKSH 4 GEN LIGHTS, P508
[6]  
CSONKA PL, 1992, WORKSH 4 GEN LIGHTS
[7]   CORONARY ANGIOGRAPHY USING SYNCHROTRON RADIATION - STUDIES IN HUMAN-SUBJECTS WITH THE SYSTEM NIKOS-II [J].
DIX, WR ;
ENGELKE, K ;
GRAEFF, W ;
HAMM, C ;
HEUER, J ;
KAEMPF, B ;
KUPPER, W ;
LOHMANN, M ;
REIME, B ;
REUMANN, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (02) :307-315
[8]  
DIX WR, 1991, P 5 INT S RAD PHYS I
[9]  
ELTON D, COMMUNICATION
[10]   Bronchial imaging in humans using xenon K-edge dichromography [J].
Giacomini, JC ;
Gordon, H ;
O'Neil, R ;
Van Kessel, A ;
Cason, B ;
Chapman, D ;
Lavendar, W ;
Gmur, N ;
Menk, R ;
Thomlinson, W ;
Zhong, Z ;
Rubenstein, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (03) :473-478