Mechanical quality factor measurements of monolithically suspended fused silica test masses of the GEO 600 gravitational wave detector

被引:17
作者
Smith, JR
Cagnoji, G
Crooks, DRM
Fejer, MM
Gossler, S
Lück, H
Rowan, S
Hough, J
Danzmann, K
机构
[1] Albert Einstein Inst, Max Planck Inst Gravitat Phys, D-30167 Hannover, Germany
[2] Leibniz Univ Hannover, D-30167 Hannover, Germany
[3] Univ Glasgow, Dept Phys & Astron, Inst Gravitat Res, Glasgow G12 8QQ, Lanark, Scotland
[4] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
关键词
D O I
10.1088/0264-9381/21/5/105
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Internal thermal noise is expected to be a limiting noise source in the most sensitive frequency band of the GEO 600 gravitational wave detector. Because thermal noise is directly related to energy dissipation, care has been taken to construct test mass suspensions from low-dissipation materials and to eliminate inter-material rubbing where possible. Recently, the GEO 600 team finished the installation of triple-pendulum suspensions for the optics of the Michelson interferometer. Each of these triple pendulums incorporates a monolithic fused silica pendulum as the lowest stage. We have made internal mode quality factor measurements of three monolithically suspended test masses. Using these measurements we estimate of the level of internal thermal noise in the GEO 600 interferometer.
引用
收藏
页码:S1091 / S1098
页数:8
相关论文
共 16 条
[1]   Status of VIRGO [J].
Acernese, F ;
Amico, P ;
Arnaud, N ;
Babusci, D ;
Barillé, R ;
Barone, F ;
Barsotti, L ;
Barsuglia, M ;
Beauville, F ;
Bizouard, MA ;
Boccara, C ;
Bondu, F ;
Bosi, L ;
Bradaschia, C ;
Bracci, L ;
Braccini, S ;
Brillet, A ;
Brisson, V ;
Brocco, L ;
Buskulic, D ;
Calamai, G ;
Calloni, E ;
Campagna, E ;
Cavalier, F ;
Cella, G ;
Chassande-Mottin, E ;
Cleva, F ;
Cokelaer, T ;
Conforto, G ;
Corda, C ;
Coulon, JP ;
Cuoco, E ;
Dattilo, V ;
Davier, M ;
De Rosa, R ;
Di Fiore, L ;
Di Virgilio, A ;
Dujardin, B ;
Eleuteri, A ;
Enard, D ;
Ferrante, I ;
Fidecaro, F ;
Fiori, I ;
Flaminio, R ;
Fournier, JD ;
Frasca, S ;
Frasconi, F ;
Gammaitoni, L ;
Gennai, A ;
Giazotto, A .
CLASSICAL AND QUANTUM GRAVITY, 2004, 21 (05) :S385-S394
[2]   Experimental measurements of coating mechanical loss factors [J].
Crooks, DRM ;
Cagnoli, G ;
Fejer, MM ;
Gretarsson, A ;
Harry, G ;
Hough, J ;
Nakagawa, N ;
Penn, S ;
Route, R ;
Rowan, S ;
Sneddon, PH .
CLASSICAL AND QUANTUM GRAVITY, 2004, 21 (05) :S1059-S1065
[3]  
GROTE H, 2003, THESIS U HANNOVER
[4]  
GWO DH, 1998, P SOC PHOTO-OPT INS, V136, P3435
[5]   Internal thermal noise in the LIGO test masses: A direct approach [J].
Levin, Y .
PHYSICAL REVIEW D, 1998, 57 (02) :659-663
[6]   Thermoelastic noise and homogeneous thermal noise in finite sized gravitational-wave test masses [J].
Liu, YT ;
Thorne, KS .
PHYSICAL REVIEW D, 2000, 62 (12) :1-10
[7]   AN INVESTIGATION OF LIMITATIONS TO QUALITY FACTOR MEASUREMENTS OF SUSPENDED MASSES DUE TO RESONANCES IN THE SUSPENSION WIRES [J].
LOGAN, JE ;
ROBERTSON, NA ;
HOUGH, J .
PHYSICS LETTERS A, 1992, 170 (05) :352-358
[8]   Test mass damping associated with electrostatic actuator [J].
Mitrofanov, VP ;
Styazhkina, NA ;
Tokmakov, KV .
CLASSICAL AND QUANTUM GRAVITY, 2002, 19 (07) :2039-2043
[9]   Thermal noise in half-infinite mirrors with nonuniform loss: A slab of excess loss in a half-infinite mirror [J].
Nakagawa, N ;
Gretarsson, AM ;
Gustafson, EK ;
Fejer, MM .
PHYSICAL REVIEW D, 2002, 65 (10)
[10]   Mechanical loss in tantala/silica dielectric mirror coatings [J].
Penn, SD ;
Sneddon, PH ;
Armandula, H ;
Betzwieser, JC ;
Cagnoli, G ;
Camp, J ;
Crooks, DRM ;
Fejer, MM ;
Gretarsson, AM ;
Harry, GM ;
Hough, J ;
Kittelberger, SE ;
Mortonson, MJ ;
Route, R ;
Rowan, S ;
Vassiliou, CC .
CLASSICAL AND QUANTUM GRAVITY, 2003, 20 (13) :2917-2928