Very long sirolimus-eluting stent implantation for de novo coronary lesions

被引:88
作者
Degertekin, M [1 ]
Arampatzis, CA [1 ]
Lemos, PA [1 ]
Saia, F [1 ]
Hoye, A [1 ]
Daemen, J [1 ]
Tanabe, K [1 ]
Lee, CH [1 ]
Hofma, SJ [1 ]
Sianos, G [1 ]
McFadden, E [1 ]
van der Giessen, W [1 ]
Smits, PC [1 ]
De Feyter, PJ [1 ]
van Domburg, RT [1 ]
Serruys, PW [1 ]
机构
[1] Erasmus Univ, Ctr Med, Dept Intervent Cardiol, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
关键词
D O I
10.1016/j.amjcard.2003.12.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Long-length stenting has a poor outcome when bare metal stents are used. The safety and efficacy of the sirolimus-eluting stent (SES) in long lesions has not been evaluated. Therefore, the aim of the present study was to evaluate the clinical and angiographic outcomes of SES implantation over a very long coronary artery segment. Since April 2002, all patients treated percutaneously at our institution received a SES as the device of choice as part of the Rapamycin Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. During the RESEARCH registry, stents were available in lengths of 8, 18, and 33 mm. The present report includes a predefined study population consisting of patients treated with > 36-mm-long stented segments. Patients had a combination of greater than or equal to 2 overlapping stents at a minimum length of 41 mm (i.e., one 33-mm SES overlapping an 8-mm SES) to treat native de novo coronary lesions. The incidence of major cardiac adverse events (death, nonfatal myocardial infarction, and target lesion revascularization) was evaluated. The study group comprised 96 consecutive patients (102 lesions). Clinical follow-up was available for all patients at a mean of 320 days (range 265 to 442). In all, 20% of long-stented lesions were chronic total occlusions, and mean stented length per lesion was 61.2 +/- 21.4 mm (range 41 to 134). Angiographic follow-up at 6 months was obtained in 67 patients (71%). Binary restenosis rate was 11.9% and in-stent late loss was 0.13 +/- 0.47 mm. At long-term follow-up (mean 320 days), there were 2 deaths (2.1%), and the overall incidence of major cardiac events was 8.3%. Thus, SES implantation appears safe and effective for de novo, coronary lesions requiring multiple stent placement over a very long vessel segment. (C) 2004 by Excerpta Medica, Inc.
引用
收藏
页码:826 / 829
页数:4
相关论文
共 11 条
  • [1] Randomized comparison of success and adverse event rates and cost effectiveness of one long versus two short stents for treatment of long coronary narrowings
    Hoffmann, R
    Herrmann, G
    Silber, S
    Braun, P
    Werner, GS
    Hennen, B
    Rupprecht, HJ
    vom Dahl, J
    Hanrath, P
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (05) : 460 - 464
  • [2] Stented segment length as an independent predictor of restenosis
    Kobayashi, Y
    De Gregorio, J
    Kobayashi, N
    Akiyama, T
    Reimers, B
    Finci, L
    Di Mario, C
    Colombo, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (03) : 651 - 659
  • [3] Procedural results and late clinical outcomes after percutaneous interventions using long (≥25 mm) versus short (<20 mm) stents
    Kornowski, R
    Bhargava, B
    Fuchs, S
    Lansky, AJ
    Satler, LF
    Pichard, AD
    Hong, MK
    Kent, KM
    Mehran, R
    Stone, GW
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (03) : 612 - 618
  • [4] Procedural results and late clinical outcomes after placement of three or more stents in single coronary lesions
    Kornowski, R
    Mehran, R
    Hong, MK
    Satler, LF
    Pichard, AD
    Kent, KM
    Mintz, GS
    Waksman, R
    Laird, JR
    Lansky, AJ
    Bucher, TA
    Popma, JJ
    Leon, MB
    [J]. CIRCULATION, 1998, 97 (14) : 1355 - 1361
  • [5] Coronary restenosis after sirolimus-eluting stent implantation - Morphological description and mechanistic analysis from a consecutive series of cases
    Lemos, PA
    Saia, F
    Ligthart, JMR
    Arampatzis, CA
    Sianos, G
    Tanabe, K
    Hoye, A
    Degertekin, M
    Daemen, J
    McFadden, E
    Hofma, S
    Smits, PC
    de Feyter, P
    van der Giessen, WJ
    van Domburg, RT
    Serruys, PW
    [J]. CIRCULATION, 2003, 108 (03) : 257 - 260
  • [6] Early outcome after sirolimus-eluting stent implantation in patients with acute coronary syndromes - Insights from the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) registry
    Lemos, PA
    Lee, CH
    Degertekin, M
    Saia, F
    Tanabe, K
    Arampatzis, CA
    Hoye, A
    van Duuren, M
    Sianos, G
    Smits, PC
    de Feyter, P
    van der Giessen, WJ
    van Domburg, RT
    Serruys, PW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (11) : 2093 - 2099
  • [7] A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.
    Morice, M
    Serruys, PW
    Sousa, JE
    Fajadet, J
    Hayashi, EB
    Perin, M
    Colombo, A
    Schuler, G
    Barragan, P
    Guagliumi, G
    Molnar, F
    Falotico, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) : 1773 - 1780
  • [8] Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    Moses, JW
    Leon, MB
    Popma, JJ
    Fitzgerald, PJ
    Holmes, DR
    O'Shaughnessy, C
    Caputo, RP
    Kereiakes, DJ
    Williams, DO
    Teirstein, PS
    Jaeger, JL
    Kuntz, RE
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (14) : 1315 - 1323
  • [9] Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses - Final results of a randomized comparison with angiographic guidance (TULIP study)
    Oemrawsingh, PV
    Mintz, GS
    Schalij, MJ
    Zwinderman, AH
    Jukema, JW
    Van der Wall, EE
    [J]. CIRCULATION, 2003, 107 (01) : 62 - 67
  • [10] Schalij MJ, 1999, CATHETER CARDIO INTE, V48, P105