Fenton and electro-Fenton methods for oxidation of H-acid and Reactive Black 5

被引:36
作者
Rao, NN
Bose, G
Khare, P
Kaul, SN
机构
[1] Natl Environm Engn Res Inst, Wastewater Technol Div, Nagpur 440020, Maharashtra, India
[2] Banaras Hindu Univ, Inst Technol, Varanasi 221005, Uttar Pradesh, India
关键词
D O I
10.1061/(ASCE)0733-9372(2006)132:3(367)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Oxidative treatment of H-acid (HA) and Reactive Black 5 (RB5) using Fenton reagent (Fe2+/H2O2) and the electro-Fenton (EF) method is reported. Optimization of doses of ferrous iron and hydrogen peroxide was carried out in each case using HA; and the oxidation of RB5 was also carried Out under the optimized conditions. Approximately 71% chemical oxygen demand (COD) was removed in 2 h using the conventional Fenton method at optimized doses: Fe2+= 0.3 g/L (5.37 mM), H2O2=6 mL/L (53.0 mM), H2O2/Fe2+= 10. In contrast, more than 92% COD was removed in 15 min using the EF method with an optimized Fe2+ dose of 0. 130 g/L (2.34 mM) and 8 ml/L (70.6 mM) of H2O2. The pseudo-first-order rate constants (k) for the Fenton reagent and EF method were 0.054 and 0.38 min(-1). The COD removal through the EF method was seven times faster. The calculated energy requirement of the EF method was 0.82 kg COD/kW(.)h at the minimum applied current (0.25 A) when approximately 92.5% COD was removed. In the case of RB5, about 67 and 87% COD was removed under optimized Fenton and electro-Fenton conditions, respectively. The higher efficiency of the EF method was attributed to incremental addition of Fe2+ and accompanying higher H2O2/Fe2+ molar ratio. The results are discussed in the light of the mechanism for Fenton's oxidation.
引用
收藏
页码:367 / 376
页数:10
相关论文
共 40 条
[1]   The removal of low level organics via hydrogen peroxide formed in a reticulated vitreous carbon cathode cell, Part 1. The electrosynthesis of hydrogen peroxide in aqueous acidic solutions [J].
Alvarez-Gallegos, A ;
Pletcher, D .
ELECTROCHIMICA ACTA, 1998, 44 (05) :853-861
[2]  
*APHA, 1998, 5220B APHA
[3]   Effect of Fe(III)-ligand properties on effectiveness of modified photo-Fenton processes [J].
Aplin, R ;
Feitz, AJ ;
Waite, TD .
WATER SCIENCE AND TECHNOLOGY, 2001, 44 (05) :23-30
[4]  
BISWAS S, 1994, INDIAN J CHEM A, V33, P10
[5]   Aniline mineralization by AOP's: anodic oxidation, photocatalysis, electro-Fenton and photoelectro-Fenton processes [J].
Brillas, E ;
Mur, E ;
Sauleda, R ;
Sanchez, L ;
Peral, J ;
Domenech, X ;
Casado, J .
APPLIED CATALYSIS B-ENVIRONMENTAL, 1998, 16 (01) :31-42
[6]   Degradation of 4-chlorophenol by anodic oxidation, electro-Fenton, photoelectro-Fenton, and peroxi-coagulation processes [J].
Brillas, E ;
Sauleda, R ;
Casado, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (03) :759-765
[7]   Chemical degradation of aromatic amines by Fenton's reagent [J].
Casero, I ;
Sicilia, D ;
Rubio, S ;
PerezBendito, D .
WATER RESEARCH, 1997, 31 (08) :1985-1995
[8]   Role of quinone intermediates as electron shuttles in Fenton and photoassisted Fenton oxidations of aromatic compounds [J].
Chen, RZ ;
Pignatello, JJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (08) :2399-2406
[9]  
CHIARENZELLI J, 1997, P 2 INT S ENV APPL A, V4, P77
[10]   Treatment of high strength hexamine-containing wastewater by Electro-Fenton method [J].
Chou, SS ;
Huang, YH ;
Lee, SN ;
Huang, GH ;
Huang, CP .
WATER RESEARCH, 1999, 33 (03) :751-759