Analysis of the sensible heat flux from the exterior surface of buildings using time sequential thermography

被引:51
作者
Hoyano, A [1 ]
Asano, K [1 ]
Kanamaru, T [1 ]
机构
[1] Tokyo Inst Technol, Dept Environm Phys & Engn, Midori Ku, Yokohama, Kanagawa 2268502, Japan
关键词
thermal infrared camera; thermography; surface temperature; external building surface; sensible heat flux;
D O I
10.1016/S1352-2310(99)00136-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, the distribution of surface temperature on the surface of two buildings having different characteristics was measured using a thermal infrared camera. Measurements were made in the summer, the period in Japan during which heat flux from buildings is of major interest, and again in the winter for comparison purposes. The heat characteristics of each building were obtained throughout the day by time-sequential thermography (TST), and the surface temperature of each physical element was classified according to temperature, shape, material and position. When the temperature of a surface could not be determined by an infrared camera mounted on the top of a building or a pole, temperature measurements were made using a hand-held IR camera. In addition, the sensible heat flux from each surface was calculated using TST and the surface area of each element as calculated from blueprints of the buildings. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3941 / 3951
页数:11
相关论文
共 3 条
[1]  
[Anonymous], 1996, BOUNDARY LAYER CLIMA
[2]  
COLE S, 1997, ASHRAE HDB BUILDING, V12
[3]  
LINO A, 1995, ENERGY BUILDINGS, V23, P199