Effect of low-density lateral interfaces on soft-tissue doses

被引:34
作者
Hunt, MA [1 ]
Desobry, GE [1 ]
Fowble, B [1 ]
Coia, LR [1 ]
机构
[1] FOX CHASE CANC CTR,DEPT RADIAT ONCOL,PHILADELPHIA,PA 19111
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 37卷 / 02期
关键词
interface dosimetry; inhomogeneities; thorax irradiation;
D O I
10.1016/S0360-3016(96)00499-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Doses at the interface between tissue and low-density inhomogeneities with the interface positioned perpendicular to the beam direction have been well studied. When the inhomogeneity lies parallel to the beam direction (i.e., a lateral interface), the resulting dose distribution is not as well known. Lateral lung-soft-tissue interfaces are common in many fields used to treat malignancies in the thorax region including tangential breast fields and anteroposterior fields for lung and esophageal cancer. The purpose of this study was to evaluate the dose distribution along lateral interfaces and to determine the implications for treatment. Methods and Materials: A polystyrene and cork slab phantom was irradiated from the side to simulate treatment fields with lateral lung-soft-tissue interfaces. The beam was positioned with the isocenter in polystyrene and the field edge in cork. Cork slabs (0.6-2.5 cm) were used to simulate different thicknesses of lung between the field edge and the target volume. Measurements were made using a parallel plate ionization chamber. With the chamber position held constant, polystyrene slabs were added between the cork and the chamber to study the dose distribution in the interface region. Interface doses were studied as a function of the amount of cork in the field, field size, beam energy (6-18 MV), and depth. Results: Doses in the interface region were lower by as much as 10% compared to doses in a homogeneous phantom. For a given cork width and field size, the magnitude of the underdose increased by several percent as the x-ray energy increased from 6 to 18 MV. The underdose at the interface was 5% for 6 MV and 8% for 18 MV X-rays with a l-cm cork width. For a 2.5-cm cork width, underdoses of 2.5% and 3% at distances up to 2.5 and 4 mm lateral to the interface were observed for 6- and 18-MV X-rays, respectively. However, doses right at the interface were 1% greater for 6 MV and 3% less for 18 MV than doses in a homogeneous phantom. For a given cork width, the interface doses were not significantly dependent on field width but decreased by an additional 2-3% as the length decreased to 4 cm. Additional decreases were also observed when the measurement depth decreased to 3 cm. With a l-cm width of cork in the field, a lateral distance of 3-4 mm from the interface was necessary to ensure doses of at least 98% of the homogenous dose with 6-MV X-rays. A lateral distance of 6-7 mm was necessary for 10- and 18-MV X rays. Conclusion: Underdosing will occur in the soft tissues adjacent to low-density inhomogeneities. The magnitude depends primarily on the width of the inhomogeneity seen in the treatment field, but also on field size, depth, and beam energy. For treatment fields with a lateral lung interface, a segment of tissue approximately 3-4 mm thick for 6 MV and 6-7 mm thick for higher-energy beams may be underdosed. Lung widths of greater than or equal to 1.75 cm as observed on film will generally guarantee doses of at least 96% of those calculated with no inhomogeneity corrections. High-energy beams are often used to treat sites in the thorax or breast to improve dose homogeneity throughout the treatment volume. Potential underdosing due to the presence of lung should be considered and may require a decrease in beam energy or an increase in the margin between the target volume and the field edge to ensure adequate treatment. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 22 条
[1]   A COMPARISON OF AIR-CAVITY INHOMOGENEITY EFFECTS FOR CO-60, 6-MV, AND 10-MV X-RAY-BEAMS [J].
BEACH, JL ;
MENDIONDO, MS ;
MENDIONDO, OA .
MEDICAL PHYSICS, 1987, 14 (01) :140-144
[2]   A PHOTON DOSE DISTRIBUTION MODEL EMPLOYING CONVOLUTION CALCULATIONS [J].
BOYER, A ;
MOK, E .
MEDICAL PHYSICS, 1985, 12 (02) :169-177
[3]   CALCULATION OF PHOTON DOSE DISTRIBUTIONS IN AN INHOMOGENEOUS-MEDIUM USING CONVOLUTIONS [J].
BOYER, AL ;
MOK, EC .
MEDICAL PHYSICS, 1986, 13 (04) :503-509
[4]   DOSIMETRY AT INTERFACES FOR HIGH ENERGY X AND GAMMA RAYS [J].
DUTREIX, J ;
BERNARD, M .
BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (459) :205-&
[5]   PITFALLS IN THE USE OF HIGH-ENERGY X-RAYS TO TREAT TUMORS IN THE LUNG [J].
EKSTRAND, KE ;
BARNES, WH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :249-252
[6]   IONIZATION BUILD-UP IN UPPER RESPIRATORY AIR PASSAGES DURING TELETHERAPY WITH COBALT 60-RADIATION [J].
EPP, ER ;
LOUGHEED, MN ;
MCKAY, JW .
BRITISH JOURNAL OF RADIOLOGY, 1958, 31 (367) :361-367
[7]   UNDERDOSING OF LESIONS RESULTING FROM LACK OF ELECTRONIC EQUILIBRIUM IN UPPER RESPIRATORY AIR CAVITIES IRRADIATED BY 10 MV X-RAY BEAMS [J].
EPP, ER ;
BOYER, AL ;
DOPPKE, KP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (7-8) :613-619
[8]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[9]   SURFACE EFFECTS HIGH-ENERGY X-RAYS AT OBLIQUE INCIDENCE [J].
JACKSON, W .
BRITISH JOURNAL OF RADIOLOGY, 1971, 44 (518) :109-&
[10]   THE INFLUENCE OF AIR CAVITIES ON INTERFACE DOSES FOR PHOTON BEAMS [J].
KLEIN, EE ;
CHIN, LM ;
RICE, RK ;
MIJNHEER, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :419-427