An improved powered ankle-foot orthosis using proportional myoelectric control

被引:233
作者
Ferris, Daniel P.
Gordon, Keith E.
Sawicki, Gregory S.
Peethambaran, Arnmanath
机构
[1] Univ Michigan, Dept Movement Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Orthot & Prosthet Ctr, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
locomotion; exoskeleton; gait; rehabilitation;
D O I
10.1016/j.gaitpost.2005.05.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We constructed a powered ankle-foot orthosis for human walking with a novel myoelectric controller. The orthosis included a carbon fiber and polypropylene shell, a metal hinge joint, and two artificial pneumatic muscles. Soleus electromyography (EMG) activated the artificial plantar flexor and inhibited the artificial dorsiflexor. Tibialis anterior EMG activated the artificial dorsiflexor. We collected kinematic, kinetic, and electromyographic data for a naive healthy subject walking with the orthosis. The current design improves upon a previous prototype by being easier to don and doff and simpler to use. The novel controller allows naive wearers to quickly adapt to the orthosis without artificial muscle co-contraction. The orthosis may be helpful in studying human walking biomechanics and assisting patients during gait rehabilitation after neurological injury. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 23 条
  • [1] [Anonymous], 1981, BIOMECHANICS MED DEV
  • [2] Does neurorehabilitation play a role in the recovery of walking in neurological populations?
    Barbeau, H
    Norman, K
    Fung, J
    Visintin, M
    Ladouceur, M
    [J]. NEURONAL MECHANISMS FOR GENERATING LOCOMOTOR ACTIVITY, 1998, 860 : 377 - 392
  • [3] Locomotor training after human spinal cord injury: A series of case studies
    Behmran, AL
    Harkema, SJ
    [J]. PHYSICAL THERAPY, 2000, 80 (07): : 688 - 700
  • [4] Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
    Blaya, JA
    Herr, H
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2004, 12 (01) : 24 - 31
  • [5] Enhanced modelling and performance in braided pneumatic muscle actuators
    Davis, S
    Tsagarakis, N
    Canderle, J
    Caldwell, DG
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2003, 22 (3-4) : 213 - 227
  • [6] Locomotor capacity and recovery of spinal cord function in paraplegic patients: a clinical and electrophysiological evaluation
    Dietz, V
    Wirz, M
    Colombo, G
    Curt, A
    [J]. ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 109 (02): : 140 - 153
  • [7] An ankle-foot orthosis powered by artificial pneumatic muscles
    Ferris, DP
    Czerniecki, JM
    Hannaford, B
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2005, 21 (02) : 189 - 197
  • [8] BIOMECHANICAL ANALYSIS OF THE INFLUENCE OF PROSTHETIC FEET ON BELOW-KNEE AMPUTEE WALKING
    GITTER, A
    CZERNIECKI, JM
    DEGROOT, DM
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1991, 70 (03) : 142 - 148
  • [9] Neural plasticity after human spinal cord injury: Application of locomotor training to the rehabilitation of walking
    Harkema, SJ
    [J]. NEUROSCIENTIST, 2001, 7 (05) : 455 - 468
  • [10] Upper and lower extremity robotic devices for rehabilitation and for studying motor control
    Hesse, S
    Schmidt, H
    Werner, C
    Bardeleben, A
    [J]. CURRENT OPINION IN NEUROLOGY, 2003, 16 (06) : 705 - 710