Performance of the automated BpTRU™ measurement device in the assessment of white-coat hypertension and white-coat effect

被引:43
作者
Culleton, BF
McKay, DW
Campbell, NR
机构
[1] Mem Univ Newfoundland, Fac Med, Dept Med, Div Nephrol, St John, NF, Canada
[2] Mem Univ Newfoundland, Fac Med, Div Basic Med Sci, St John, NF A1B 3V6, Canada
[3] Univ Calgary, Fac Med, Dept Med, Div Gen Internal Med,Cardiovasc Res Grp, Calgary, AB, Canada
[4] Univ Calgary, Fac Med, Dept Pharmacol, Div Gen Internal Med,Cardiovasc Res Grp, Calgary, AB, Canada
[5] Univ Calgary, Fac Med, Dept Therapeut, Div Gen Internal Med,Cardiovasc Res Grp, Calgary, AB, Canada
关键词
automated blood pressure; blood pressure measurement; BpTRU; clinical trial; hypertension; misclassification; white-coat effect; white-coat hypertension;
D O I
10.1097/01.mbp.0000189794.36230.a7
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives BpTRU (VSM MedTech Ltd, Vancouver, Canada) is an automated oscillometric device that provides serial blood pressure measurements in an office setting in the absence of a healthcare professional. We sought to determine whether the white-coat effect is reduced by a blood pressure measurement protocol using BpTRU compared with casual office measurements. Secondarily, we also sought to determine whether a blood pressure measurement protocol using BpTRU reduced white-coat hypertension compared with the casual office measurements, and reduced white-coat effect and white-coat hypertension compared with blood pressure obtained by a research nurse. Methods Blood pressure was measured in 107 adult hypertensive patients referred for ambulatory blood pressure monitoring using an ambulatory blood pressure monitor, a standardized protocol by a trained research nurse, and a protocol using BpTRU (five readings over 25 min, using the 5-min blood pressure measurement interval setting). Casual office blood pressure was also recorded in the family physicians' offices. Using the mean daytime ambulatory blood pressure as the reference standard, the proportion of patients with white-coat effect and white-coat hypertension were determined for measurements obtained by BpTRU, the research nurse, and the family physicians' offices. Results Casual office blood pressure measurements demonstrated a white-coat effect in 39 (36.4%) patients; seven (6.5%) patients demonstrated a white-coat effect using BpTRU (P < 0.0001). White-coat hypertension was also less common using BpTRU than with the casual office readings (13 vs. 1 patient, P < 0.0001). White-coat effect was also reduced with BpTRU compared with the research nurse measurements. Unfortunately, percentage agreement for the diagnosis of hypertension between the protocol using BpTRU and the reference standard was only 48%. This resulted in substantial misclassification of hypertension by the BpTRU measurement protocol. Conclusions Although BpTRU reduces white-coat effect and white-coat hypertension, blood pressure is underestimated by the device, leading to misclassification of hypertension. BpTRU, when set at 5-min blood pressure measurement intervals, should not be used in clinical practice.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 18 条
[1]  
Campbell N R, 1999, Blood Press Monit, V4, P71, DOI 10.1097/00126097-199902000-00003
[2]  
Campbell NRC, 1999, CAN MED ASSOC J, V161, P277
[3]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[4]   Prognostic value of ambulatory blood-pressure recordings in patients with treated hypertension [J].
Clement, DL ;
De Buyzere, ML ;
De Bacquer, DA ;
de Leeuw, PW ;
Duprez, DA ;
Fagard, RH ;
Gheeraert, PJ ;
Missault, LH ;
Braun, JJ ;
Six, RO ;
Van Der Niepen, P ;
O'Brien, E .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (24) :2407-2415
[5]   Clinical decision-making in hypertension using an automated (BpTRU™) measurement device [J].
Graves, JW ;
Nash, C ;
Burger, K ;
Bailey, K ;
Sheps, SG .
JOURNAL OF HUMAN HYPERTENSION, 2003, 17 (12) :823-827
[6]   INCREASED ABSENTEEISM FROM WORK AFTER DETECTION AND LABELING OF HYPERTENSIVE PATIENTS [J].
HAYNES, RB ;
SACKETT, DL ;
TAYLOR, DW ;
GIBSON, ES ;
JOHNSON, AL .
NEW ENGLAND JOURNAL OF MEDICINE, 1978, 299 (14) :741-744
[7]  
Hemmelgarn BR, 2004, CAN J CARDIOL, V20, P31
[8]   Overall accuracy of the BpTRU™ -: an automated electronic blood pressure device [J].
Mattu, GS ;
Heran, BS ;
Wright, JM .
BLOOD PRESSURE MONITORING, 2004, 9 (01) :47-52
[9]  
MCKAY DW, 1990, J HUM HYPERTENS, V4, P639
[10]  
*MED TECHN PRACT P, 1987, J CLIN HYPERTENS, V3, P757