How to assess the limits of ion-selective electrodes:: Method for the determination of the ultimate span, response range, and selectivity coefficients of neutral carrier-based cation selective electrodes

被引:26
作者
Bereczki, R
Takács, B
Langmaier, J
Neely, M
Gyurcsányi, RE
Tóth, K
Nagy, G
Lindner, E [1 ]
机构
[1] Univ Memphis, Joint Grad Program Biomed Engn, Memphis, TN 38152 USA
[2] Univ Tennessee, Herff Coll Engn, Hlth Sci Ctr, Memphis, TN 38152 USA
[3] Budapest Univ Technol & Econ, Hungarian Acad Sci, Res Grp Tech Analyt Chem, H-1111 Budapest, Hungary
[4] Budapest Univ Technol & Econ, Dept Gen & Analyt Chem, H-1111 Budapest, Hungary
[5] Univ Pecs, Dept Gen & Phys Chem, H-7624 Pecs, Hungary
[6] J Heyrovsky Inst Phys Chem, Prague 18223 8, Czech Republic
关键词
D O I
10.1021/ac050614s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The span and range of an ion-selective electrode (ISE) has been identified by IUPAC as a potential or activity difference between the upper and lower detection limits of the electrode. Once the span is known, the ultimately attainable detection limit of the ISE can be calculated using its theoretical response slope. In this paper, we propose an original method for the determination of the ultimate span and response range of ISEs. The simple measurement of span is recommended to aid the fast screening of novel ionophores and help to focus optimization processes to the most promising candidates. The measurement of span is combined with a generally applicable procedure for the determination of the three seminal parameters of ISEs: the response slope, the ultimate selectivity coefficients, and detection limit. In the proposed procedure, following the span measurement, two subsequent exponential dilution experiments are completed in which the responses of the electrode for the primary and the interfering ions are tested using a solution of a discriminated ion and deionized water as diluting electrolytes in consecution. The advantages and the practical usefulness of the proposed methods and procedures are demonstrated through the evaluation of the performance characteristics of novel and well-characterized ionophore-based potassium and calcium sensors.
引用
收藏
页码:942 / 950
页数:9
相关论文
共 37 条
[1]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[2]  
Bakker E, 2004, TALANTA, V63, P3, DOI 10.1016/j.talanta.2003.10.006
[3]   The new wave of ion-selective electrodes. [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :420A-426A
[4]  
Bakker E, 1999, ELECTROANAL, V11, P915, DOI 10.1002/(SICI)1521-4109(199909)11:13<915::AID-ELAN915>3.0.CO
[5]  
2-J
[6]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[7]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[8]  
Bedlechowicz W, 2002, J ELECTROANAL CHEM, V537, P111
[9]   Synthesis and characterization of covalently immobilized bis-crown ether based potassium ionophore [J].
Bereczki, R ;
Gyurcsányi, RE ;
Agai, B ;
Tóth, K .
ANALYST, 2005, 130 (01) :63-70
[10]   Synthesis and alkali cation extraction ability of new mono and bis(benzocrown ether)s with terminal alkenyl groups [J].
Bereczki, R ;
Agai, B ;
Bitter, I .
JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2003, 47 (1-2) :53-58