Multislice CT-image-guided endoscopic sinus surgery using an electromagnetic tracking system

被引:20
作者
Reittner, P
Tillich, M
Luxenberger, W
Weinke, R
Preidler, K
Köle, W
Stammberger, H
Szolar, D
机构
[1] Karl Franzens Med Sch, Dept Radiol, A-8036 Graz, Austria
[2] Univ Hosp, Graz, Austria
[3] Karl Franzens Med Sch, Dept ENT, A-8036 Graz, Austria
[4] Univ Hosp Graz, A-8036 Graz, Austria
[5] Diagnostikum Graz Sudwest, A-8045 Graz, Austria
关键词
computer-assisted surgery; head and neck; electromagnetic tracking system; sinus surgery; multislice CT;
D O I
10.1007/s00330-001-1200-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to assess the practicability and accuracy of a computer-assisted multislice CT-guided frameless electromagnetic c tracking for endoscopic sinus surgery. Eighty-two patients with various paranasal sinus diseases were evaluated. Prior to surgery, axial multislice spiral-CT scans with 2.5-mm collimation, 0.8-mm reconstruction increment, and a pitch of 3 were acquired. After Ethernet transfer of the CT data set to the guidance system, coronal and sagittal images were reconstructed, For intraoperative navigation the Insta Trak System (Visualization Technology, Boston. Mass.) was used. Navigational procedures are described in detail in the paper. Accuracy was assessed by means of visual landmarks which could be clearly identified endoscopically as well as on CT images. A second parameter for accuracy was calculated by the system itself as the root mean square (RMS). The system was able to display the position of the aspirating tip relative to anatomical structures with an average accuracy of 0.70+/-0.40 mm. Root mean square values showed a mean value of 0.40+/-0.20 mm. During surgical procedures the Insta Trak System provides the surgeon with additional image-based information to the endoscopic view. The device accuracy is high and the system proves to be practicable and efficient in ENT surgery.
引用
收藏
页码:592 / 596
页数:5
相关论文
共 12 条
[1]   Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses [J].
Czechowski, J ;
Janeczek, J ;
Kelly, G ;
Johansen, J .
EUROPEAN RADIOLOGY, 2001, 11 (04) :711-713
[2]  
FREYSINGER W, 1996, OTO RHINO LARYN NOVA, V6, P223
[3]   Image-guided endoscopic surgery: Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system [J].
Fried, MP ;
Kleefield, J ;
Gopal, H ;
Reardon, E ;
Ho, BT ;
Kuhn, FA .
LARYNGOSCOPE, 1997, 107 (05) :594-601
[4]   Intraoperative image guidance during endoscopic sinus surgery [J].
Fried, MP ;
Kleefield, J ;
Jolesz, FA ;
Hsu, LG ;
Gopal, HV ;
Deshmukh, V ;
Taylor, RJ ;
Morrison, PR .
AMERICAN JOURNAL OF RHINOLOGY, 1996, 10 (06) :337-342
[5]   Computer-assisted surgery in the frontal and maxillary sinus [J].
Gunkel, AR ;
Freysinger, W ;
Thumfart, WF .
LARYNGOSCOPE, 1997, 107 (05) :631-633
[6]  
KENNEDY DW, 1985, ARCH OTOLARYNGOL, V111, P576
[7]   Computer assisted localization in endoscopic sinus surgery -: The Insta Trak system. [J].
Luxenberger, W ;
Köle, W ;
Stammberger, H ;
Reittner, P .
LARYNGO-RHINO-OTOLOGIE, 1999, 78 (06) :318-325
[8]   FUNCTIONAL ENDOSCOPIC SINUS SURGERY - ANATOMY, CT SCREENING, INDICATIONS, AND COMPLICATIONS [J].
MAFEE, MF ;
CHOW, JM ;
MEYERS, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) :735-744
[9]  
STAMMBERGER H, 1991, FUNCTIONAL ENDOSCOPI, P273
[10]  
Vorbeck F, 2000, RADIOLOGE, V40, P227, DOI 10.1007/s001170050661