Design and evaluation of the Clear-PEM scanner for positron emission mammography

被引:90
作者
Abreu, MC [1 ]
Aguiar, JD
Almeida, FG
Almeida, P
Bento, P
Carrico, B
Ferreira, M
Ferreira, NC
Gonçalves, F
Leong, C
Lopes, F
Lousa, P
Martins, MV
Matela, N
Mendes, PR
Moura, R
Nobre, J
Oliveira, N
Ortigao, C
Peralta, L
Pereira, R
Rego, J
Ribeiro, R
Rodrigues, P
Sampaio, J
Santos, AI
Silva, L
Silva, JC
Sousa, P
Teixeira, IC
Teixeira, JP
Trindade, A
Varela, J
机构
[1] LIP, Lab Instrumentacao & Fis Expt Particulas, Algarve, Portugal
[2] Univ Algarve, Fac Ciencias & Tecnol, Faro, Portugal
[3] INEGI, Inst Eng Mecan Gestao Ind, Oporto, Portugal
[4] Univ Porto, Fac Engn, P-4100 Oporto, Portugal
[5] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, P-1699 Lisbon, Portugal
[6] INESC ID, Lisbon, Portugal
[7] INOV, Lisbon, Portugal
[8] Lab Instrumentacao & Fis Expt Particulas, Lisbon, Portugal
[9] Univ Tecn Lisboa, IST, Lisbon, Portugal
[10] Univ Coimbra, Fac Med, IBILI, Coimbra, Portugal
[11] Hosp Garcia Orta, Almada, Portugal
[12] CERN, Geneva, Switzerland
关键词
avalanche photodiodes; biomedical imaging; gamma-ray detectors; image reconstruction; positron emission mammography; positron emission tomography; simulation software;
D O I
10.1109/TNS.2006.870173
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design and evaluation of the imaging system Clear-PEM for positron emission mammography, under development by the PEM Consortium within the framework of the Crystal Clear Collaboration at CERN, is presented. The proposed apparatus is based on fast, segmented., high atomic number radiation sensors with depth-of-interaction measurement capabilities, and state-of-the-art data acquisition techniques. The camera consists of two compact and planar detector heads with dimensions 16.5 x 14.5 cm(2) for breast and axilla imaging. Low-noise integrated electronics provide signal amplification and analog multiplexing based on a new data-driven architecture. The coincidence trigger and data acquisition architecture makes extensive use of pipeline processing structures and multi-event memories for high efficiency up to a data acquisition rate of one million events/s. Experimental validation of the detection techniques, namely the basic properties of the radiation sensors and the ability to measure the depth-of-interaction of the incoming photons, are presented. System performance in terms of detection sensitivity, count-rates and reconstructed image spatial resolution were also evaluated by means of a detailed Monte Carlo simulation and an iterative image reconstruction algorithm.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 40 条
  • [1] ALBUQUERQUE E, 2004, MED IM C MIC IEEE RO
  • [3] Algorithms to identify detector Compton scatter in PET modules
    Comanor, KA
    Virador, PRG
    Moses, WW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2213 - 2218
  • [4] maxPET: A dedicated mammary and axillary region PET imaging system for breast cancer
    Doshi, NK
    Silverman, RW
    Shao, Y
    Cherry, SR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 811 - 815
  • [5] ECKERMAN KF, 1996, HLTH SCI RES DIVISIO
  • [6] Dedicated PET scanners for breast imaging
    Freifelder, R
    Karp, JS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) : 2463 - 2480
  • [7] Cancer statistics, 2000
    Greenlee, RT
    Murray, T
    Bolden, S
    Wingo, PA
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 2000, 50 (01) : 7 - 33
  • [8] Effect of 176Lu background on singles transmission for LSO-based PET cameras
    Huber, JS
    Moses, WW
    Jones, WF
    Watson, CC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19) : 3535 - 3541
  • [9] ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA
    HUDSON, HM
    LARKIN, RS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 601 - 609
  • [10] *ICRU MEAS, 46 ICRU MEAS