Determination of strong binding chelators and their metal complexes by anion-exchange chromatography and inductively coupled plasma mass spectrometry

被引:48
作者
Ammann, AA [1 ]
机构
[1] EAWAG, Swiss Fed Inst Environm Sci & Technol, CH-8600 Dubendorf, Switzerland
关键词
inductively coupled plasma mass spectrometry; chelators; metal complexes; polycarboxylic acids;
D O I
10.1016/S0021-9673(01)01607-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Based on the negative charge of polycarboxylic chelators, an anion-exchange separation has been developed that is compatible with sensitive metal detection by ICP-MS. A low capacity hydrophilic polymer (AS 11) was used as the anion exchanger and ammonium nitrate as the eluent. The new procedure provided high selectivity in the isocratic mode as well as a large separation window and high separation efficiency in the gradient mode. This was demonstrated for different types of chelators and their metal complexes, The aminopolycarboxylates NTA, EDTA, CDTA, DTPA, EDDS and for the EDTA derivatives HEDTA, ED3A and EDTMP, the phosphonic acid analogue of EDTA were tested. Their retention times generally depended on the charge, which was lower in 1:1 metal chelator complexes. Evaluation of the separation mechanism demonstrated that they were all separated predominantly by an anion-exchange mechanism with only a minor contribution from hydrophobic attraction. The method is useful for species identification and for predicting the charge of unknown analogous species from retention times. A gradient separation procedure achieved on-column preconcentration and matrix removal for the interference-free detection of metal chelates down to low nanomolar concentration in samples from various fields of environmental research. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:205 / 216
页数:12
相关论文
共 55 条
[1]  
Ackley K. L., 2000, COMPREHENSIVE ANAL C, V33, P249
[2]  
AMMANN AA, IN PRESS FRESENIUS J
[3]  
[Anonymous], 1978, SPECTROCHIM ACTA, VB33, P242
[4]   Analysis of polar organic micropollutants in water with ion chromatography electrospray mass spectrometry [J].
Bauer, KH ;
Knepper, TP ;
Maes, A ;
Schatz, V ;
Voihsel, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 837 (1-2) :117-128
[5]   THE ANALYSIS OF EDTA IN WATER BY HPLC [J].
BERGERS, PJM ;
DEGROOT, AC .
WATER RESEARCH, 1994, 28 (03) :639-642
[6]   DETERMINATION OF FREE NITRILOTRIACETIC ACID IN ENVIRONMENTAL WATER SAMPLES BY ION CHROMATOGRAPHY WITH POTENTIOMETRIC AND AMPEROMETRIC DETECTION WITH A COPPER ELECTRODE [J].
BUCHBERGER, W ;
HADDAD, PR ;
ALEXANDER, PW .
JOURNAL OF CHROMATOGRAPHY, 1991, 546 (1-2) :311-315
[7]   DETERMINATION OF CHELATING-AGENTS AND METAL-CHELATES BY CAPILLARY ZONE ELECTROPHORESIS [J].
BUCHBERGER, W ;
MULLEDER, S .
MIKROCHIMICA ACTA, 1995, 119 (1-2) :103-111
[8]   Environmental fate and microbial degradation of aminopolycarboxylic acids [J].
Bucheli-Witschel, M ;
Egli, T .
FEMS MICROBIOLOGY REVIEWS, 2001, 25 (01) :69-106
[9]   Determination of EDTA, NTA, and other amino carboxylic acids and their Co(II) and Co(III) complexes by capillary electrophoresis [J].
Burgisser, CS ;
Stone, AT .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (09) :2656-2664
[10]   The stability of some metal EDTA, DTPA and DOTA complexes:: Application as tracers in groundwater studies [J].
Byegård, J ;
Skarnemark, G ;
Skålberg, M .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 241 (02) :281-290