Monitoring of taints related to printed solid boards with an electronic nose

被引:12
作者
Heiniö, RL [1 ]
Ahvenainen, R [1 ]
机构
[1] VTT Biotechnol, FIN-02044 Espoo, Finland
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2002年 / 19卷
关键词
taint; electronic nose; headspace; sensory; board; printing;
D O I
10.1080/02652030110072083
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The main objectives were to combine knowledge gathered from the electronic nose (EN) with traditional analytical reference methods for measuring volatile compounds, such as sensory and headspace methods. The impacts of different colouring agents on the sensory properties of packaging materials when analysed by EN were determined. The first step in investigations using the EN was optimization of sample treatment and analysis parameters for the samples. The best resolution was achieved at 60degrees C in 20 min, and the effect of humidity on the EN sensors was confirmed. A comparison was made of three sensory methods for analysing taints of packaging materials. The study showed that the odour of the packaging itself was often not a reliable indication of the taint perceived in the packed foodstuff and should he regarded only as indicative. Taints caused by pigments of printed solid boards were analysed by EN. Twenty samples were studied, representing imprinted solid board, lacquered solid board, offset printed solid board with 14 different colours and offset printed, lacquered solid board with four colours. The EN succeeded in grouping these materials according to their colouring agents or lacquering, despite slight overlapping of replicates, and the results appeared to reflect at least to sonic extent the off-flavours perceived in sensory evaluation. The results of this study are only indicative, because the analysis of results from different sources or equipment requires more extensive use of statistical methods.
引用
收藏
页码:209 / 220
页数:12
相关论文
共 15 条
[1]  
CULTER J, 1998, FOOD COSMETICS D JAN, P15
[2]   Taint and odour related quality monitoring of two food packaging board products using gas chromatography, gas sensors and sensory analysis [J].
Forsgren, G ;
Frisell, H ;
Ericsson, B .
NORDIC PULP & PAPER RESEARCH JOURNAL, 1999, 14 (01) :5-16
[3]  
FORSGREN G, 1999, THESIS LINKOPING STU
[4]  
FORSGREN G, 1997, NORD PULP PAP RES J, V12, P276
[5]  
GRIFFITHS NM, 1993, EC FLAIR SENS 2, V1, P21
[6]  
HEINIO RL, 1994, EC FLAIR SENS 3, V4, P100
[7]   IDENTIFICATION OF PAPER QUALITY USING A HYBRID ELECTRONIC NOSE [J].
HOLMBERG, M ;
WINQUIST, F ;
LUNDSTROM, I ;
GARDNER, JW ;
HINES, EL .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 27 (1-3) :246-249
[8]  
Ljungberg Willing B.-I., 1998, PACKAGING TECHNOLOGY, V11, P59
[9]  
RANDELL K, 1996, P INT S FOOD PACK EN
[10]   Optimisation of electronic nose measurements. Part II: Influence of experimental parameters [J].
Roussel, S ;
Forsberg, G ;
Grenier, P ;
Bellon-Maurel, V .
JOURNAL OF FOOD ENGINEERING, 1999, 39 (01) :9-15