The effect of acetabular cup orientations on limiting hip rotation

被引:153
作者
Kummer, FJ [1 ]
Shah, S [1 ]
Iyer, S [1 ]
DiCesare, PE [1 ]
机构
[1] Hosp Joint Dis Orthopaed Inst, New York, NY 10003 USA
关键词
acetabular cup; rotation; range of motion; cup version; cup position; augmented cup;
D O I
10.1016/S0883-5403(99)90110-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The orientation of the acetabular cup and position of lip augmentation (if present) may improve postoperative total hip replacement stability by decreasing dislocation caused by hip prosthesis impingement during rotation. To determine how these cup parameters affect dislocation, the range and amount of rotation for two standard femoral components was determined in a Sawbones hemipelvis model. The parameters that allowed for maximal range of rotation were a cup angle of inclination between 35 degrees and 45 degrees and cup anteversion between 0 degrees and 10 degrees. Cup anteversion angles greater than 20 degrees and cup angles of inclination greater than 45 degrees significantly limited internal and external rotation, particularly for hip flexion greater than 60 degrees. The position of the cup lip augmentation did not affect the amount of rotation except when the hip was flexed and the lip superiorly oriented. Although there are currently devices to facilitate a particular cup position, hip stem type and orientation are other important factors affecting range of rotation that must be considered.
引用
收藏
页码:509 / 513
页数:5
相关论文
共 11 条
[1]  
[Anonymous], 1965, JOINT MOT METH MEAS
[2]  
CHANDLER DR, 1982, CLIN ORTHOP RELAT R, P284
[3]  
HOGAN V, 1997, THESIS TULANE U NEW
[4]  
JARAMAZ B, 1997, T 43 ORTH RES SOC, P286
[5]  
Krushell R J, 1991, J Arthroplasty, V6, P97, DOI 10.1016/S0883-5403(11)80002-1
[6]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[7]  
MIAN SW, 1992, CLIN ORTHOP RELAT R, P206
[8]   DISLOCATION OF TOTAL HIP REPLACEMENTS - A COMPARATIVE-STUDY OF STANDARD, LONG POSTERIOR WALL AND AUGMENTED ACETABULAR COMPONENTS [J].
NICHOLAS, RM ;
ORR, JF ;
MOLLAN, RAB ;
CALDERWOOD, JW ;
NIXON, JR ;
WATSON, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (03) :418-422
[9]  
O'Brien S, 1996, Nurs Stand, V11, P39
[10]   CAUSES OF DISLOCATION OF TOTAL HIP-ARTHROPLASTY - CT STUDY OF COMPONENT ALIGNMENT [J].
PIERCHON, F ;
PASQUIER, G ;
COTTEN, A ;
FONTAINE, C ;
CLARISSE, J ;
DUQUENNOY, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :45-48