Rapid protein digestion and identification using monolithic enzymatic microreactor coupled with nano-liquid chromatography-electro spray ionization mass spectrometry

被引:76
作者
Duan, JC [1 ]
Sun, LL [1 ]
Liang, Z [1 ]
Zhang, J [1 ]
Wang, H [1 ]
Zhang, LH [1 ]
Zhang, WB [1 ]
Zhang, YK [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog Res & Anal Ctr, Dalian 116023, Peoples R China
关键词
monolithic column; enzymatic reactor; protein identification; nano-liquid chromatography-tandem mass spectrometry;
D O I
10.1016/j.chroma.2005.11.102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel monolithic enzymatic microreactor was prepared in the fused-silica capillary by in situ polymerization of acrylamide (AA), Nacryloxysuccinimide (NAS) and ethylene dimethacrylate (EDMA) in the presence of a binary porogenic mixture of dodecanol and cyclohexanol, which could offer very low back pressure, enabling the fast digestion of proteins. The performance of the monolithic microreactor was demonstrated by digesting cytochrome c at high flow rate, and the comparisons between the in-solution digestion and on-column reaction were made by a nano-high performance liquid chromatography-mass spectrometry (nano-fIPLC-MS) system. The performance of the monolithic microreactor was demonostrated with the digestion of cytochrome c at the fast flow rate of 1 mu L-min, which afforded a residence time of 7 s, yielding a sequence coverage of 54.81% using strict multiple database searching thresholds. Furture more, a mixture of four standard proteins was digested and analyzed using the on-line digestion and nano-HPLC-MS system. The results showed the promising of such a system in the analysis of protein mixture. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 52 条
[1]   Mass spectrometry in proteomics [J].
Aebersold, R ;
Goodlett, DR .
CHEMICAL REVIEWS, 2001, 101 (02) :269-295
[2]   Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix [J].
Bengtsson, M ;
Ekström, S ;
Marko-Varga, G ;
Laurell, T .
TALANTA, 2002, 56 (02) :341-353
[3]   Reproducibility of a solid-phase trypsin microreactor for peptide mapping by capillary electrophoresis [J].
Bonneil, E ;
Mercier, M ;
Waldron, KC .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :29-45
[4]   Development of a bioreactor based on trypsin immobilized on monolithic support for the on-line digestion and identification of proteins [J].
Calleri, E ;
Temporini, C ;
Perani, E ;
Stella, C ;
Rudaz, S ;
Lubda, D ;
Mellerio, G ;
Veuthey, JL ;
Caccialanza, G ;
Massolini, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :99-109
[5]   Trypsin-based monolithic bioreactor coupled on-line with LC/MS/MS system for protein digestion and variant identification in standard solutions and serum samples [J].
Calleri, E ;
Temporini, C ;
Perani, E ;
De Palma, A ;
Lubda, D ;
Mellerio, G ;
Sala, A ;
Galliano, M ;
Caccialanza, G ;
Massolini, G .
JOURNAL OF PROTEOME RESEARCH, 2005, 4 (02) :481-490
[6]  
Chang JP, 1997, RAPID COMMUN MASS SP, V11, P1266, DOI 10.1002/(SICI)1097-0231(199708)11:12<1266::AID-RCM977>3.0.CO
[7]  
2-3
[8]   Membrane-based nanoscale proteolytic reactor enabling protein digestion, peptide separation, and protein identification using mass spectrometry [J].
Cooper, JW ;
Chen, JZ ;
Li, Y ;
Lee, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (05) :1067-1074
[9]   Charting the protein complexome in yeast by mass spectrometry [J].
Deshaies, RJ ;
Seol, JH ;
McDonald, WH ;
Cope, G ;
Lyapina, S ;
Shevchenko, A ;
Shevchenko, A ;
Verma, R ;
Yates, JR .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (01) :3-10
[10]   Automated nanoflow liquid chromatography-tandem mass spectrometry for a differential display proteomic study on Xenopus laevis neuroendocrine cells [J].
Devreese, B ;
Janssen, KPC ;
Vanrobaeys, F ;
Van Herp, F ;
Martens, GJM ;
Van Beeumen, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) :113-121