Using Theoretical Correction Factors for Quantitative Analysis of Sterols and Sterol Concentrates

被引:9
作者
Costin, Colin D. [1 ]
Hansen, Steven L. [1 ]
Chambers, Daniel P. [1 ]
机构
[1] Cargill Inc, Global Food Res, Adv Analyt, Wayzata, MN 55391 USA
关键词
Theoretical correction factors (TCF); Sterols; Gas chromatography; Flame ionization detection; Data analysis; GAS-LIQUID-CHROMATOGRAPHY; ACID METHYL-ESTERS; HIGH-ACCURACY; RESPONSE FACTORS; RELIABILITY; OILS;
D O I
10.1007/s11746-008-1332-9
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A common detector for the analysis of sterols and sterol concentrates by gas chromatography is the flame ionization detector (FID). The detector measures the response of ions from a molecule as it is pyrolyzed in a hydrogen flame. The response is relative to the number of hydrogen and carbon atoms in a molecule and it gives different responses for the same amounts of different analytes. Theoretical correction factors (TCF) can be used to account for these differences during data analysis and are based upon the number of active carbons in a molecule and can be calculated from known structures. TCF have been used to provide a more reproducible approach to the analysis of sterol concentrates in raw materials. Use of empirical correction factors (ECF) requires determination of relative responses for each analyte and also a high purity standard (and determination of that purity), which can be expensive or difficult to obtain for the more uncommon sterols. Experiments have been conducted to determine ECF for Ergost-5-en-3-ol, (3 beta,24R), commonly known as campesterol, Stigmasta-5,22-dien-3-ol, (3 beta,22E), commonly known as stigmasterol, and Stigmast-5-en-3-ol, (3 beta), commonly known as beta-sitosterol and compared to the calculated TCF for these same sterols. The experiments evaluated differences in concentration, standard purity, and injection technique and found that all three factors had an effect on the determination of ECF. It was also found that cool on column injections gave more accurate ECF values and are preferable for quantitative analysis of sterols.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 13 条
[1]   APPLICATION OF SPECIFIC RESPONSE FACTORS IN GAS CHROMATOGRAPHIC ANALYSIS OF METHYL ESTERS OF FATTY ACIDS WITH FLAME IONIZATION DETECTORS [J].
ACKMAN, RG ;
SIPOS, JC .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1964, 41 (05) :377-&
[2]  
Aizetmueller K., 1998, Fett/Lipid, V100, P429, DOI 10.1002/(SICI)1521-4133(199809)100:9<429::AID-LIPI429>3.3.CO
[3]  
2-7
[4]  
[Anonymous], 1997, 691 CH AOCS
[5]  
*AOCS, 2005, 1H05 CE AOCS
[6]   ANALYSIS OF FATTY-ACID METHYL-ESTERS WITH HIGH-ACCURACY AND RELIABILITY .6. RAPID ANALYSIS BY SPLIT INJECTION CAPILLARY GAS-LIQUID-CHROMATOGRAPHY [J].
BANNON, CD ;
CRASKE, JD ;
FELDER, DL ;
GARLAND, IJ ;
NORMAN, LM .
JOURNAL OF CHROMATOGRAPHY, 1987, 407 :231-241
[7]   ANALYSIS OF FATTY-ACID METHYL-ESTERS WITH HIGH-ACCURACY AND RELIABILITY .5. VALIDATION OF THEORETICAL RELATIVE RESPONSE FACTORS OF UNSATURATED ESTERS IN THE FLAME IONIZATION DETECTOR [J].
BANNON, CD ;
CRASKE, JD ;
HILLIKER, AE .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1986, 63 (01) :105-110
[8]   GAS-LIQUID-CHROMATOGRAPHY ANALYSIS OF THE FATTY-ACID COMPOSITION OF FATS AND OILS - A TOTAL SYSTEM FOR HIGH-ACCURACY [J].
CRASKE, JD ;
BANNON, CD .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1987, 64 (10) :1413-1417
[9]  
ETTRE LS, 1963, J CHROMATOGR, V2, P114
[10]   HIGH-RESOLUTION GC OF UNSAPONIFIABLE MATTER AND STEROL FRACTION IN VEGETABLE-OILS [J].
FREGA, N ;
BOCCI, F ;
GIOVANNONI, G ;
LERCKER, G .
CHROMATOGRAPHIA, 1993, 36 :215-217