Resolution and chemical formula identification of aromatic hydrocarbons and aromatic compounds containing sulfur, nitrogen, or oxygen in petroleum distillates and refinery streams

被引:118
作者
Guan, SH
Marshall, AG
Scheppele, SE
机构
[1] FLORIDA STATE UNIV,NATL HIGH MAGNET FIELD LAB,CTR INTERDISCIPLINARY MAGNET RESONANCE,TALLAHASSEE,FL 32310
[2] AMOCO RES CTR,NAPERVILLE,IL 60566
[3] UNIV ILLINOIS,RES RESOURCES CTR,CHICAGO,IL 60612
关键词
D O I
10.1021/ac9507855
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An all-glass heated inlet system has been interfaced to a dual-trap Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. The inlet vaporizes a mixture of species of widely different boiling points, and the interface maintains a large (factor of 10(10)) pressure gradient between the inlet and the mass spectrometer, making possible the analysis of petroleum distillates and refinery streams at very high mass resolution, Ions generated by low-energy electron ionization in the source trap of the spectrometer are transferred to the analyzer trap, where the pressure is at least 2 orders of magnitude lower. Singly-charged ions from a mass window of similar to 20 u are isolated by stored-waveform radial ejection, to reduce space charge and increase digital resolution: routine mass resolving power >200 000 (based on magnitude-mode peak full width at half-height) is thereby achieved throughout the full mass window, The mass window may be incremented stepwise to cover the full mass range of several hundred units, The FT-ICR mass spectrum of a gas oil aromatic neutral fraction contained peaks resulting from the resolution of ions having 358 distinct formulas over a mass range of similar to 42 u, C-3/SH4, C-13/CH, (CH)-C-13/N, CH2/N, and other mass doublets were baseline-resolved, yielding typical mass measurement inaccuracies of similar to 1 ppm, For example, (CC17H20S+)-C-13-C-12 and C21H17+, which differ by only 0.0011 u at similar to 269 u, were clearly resolved. A 40 000 resolving power low-voltage spectrum of the aromatic neutrals, acquired by use of a Kratos MS-50 double-focusing instrument, was processed with a computer-based deisotoping/formula assignment procedure, The algorithm of the program is outlined and illustrated, Remarkably good agreement exists between the FT-ICR and MS-50 results, However, instrumental rather than indirect resolution of ions clearly enhances analytical accuracy and significantly reduces dataprocessing time, Thus, we have demonstrated that FT-ICR is the mass analysis of choice for differentiating hydrocarbons from heteroatom-containing compounds in petroleum distillates and refinery streams.
引用
收藏
页码:46 / 71
页数:26
相关论文
共 66 条
[1]   COMPUTER TECHNIQUES FOR QUANTITATIVE HIGH RESOLUTION MASS SPECTRAL ANALYSES OF COMPLEX HYDROCARBON MIXTURES [J].
ACZEL, T ;
ALLAN, DE ;
HARDING, JH ;
KNIPP, EA .
ANALYTICAL CHEMISTRY, 1970, 42 (03) :341-&
[2]  
Aczel T., 1978, ANAL METHODS COAL CO, V1, P499
[3]  
ACZEL T, 1971, REV ANAL CHEM, V1, P226
[4]  
ACZEL T, 1977, CHEM PROPERTIES SYNT
[5]  
ASAMOTO B, 1991, ANAL APPLICATIONS FO
[6]   EXPERIMENTAL EVALUATION OF APODIZATION FUNCTIONS FOR QUANTITATIVE FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BRENNA, JT ;
CREASY, WR .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 90 (02) :151-166
[7]  
CARLSON EG, 1963, ADV MASS SPECTROM, V2, P377
[8]   POLYCYCLIC AROMATIC STRUCTURE DISTRIBUTIONS BY HIGH-RESOLUTION MASS-SPECTROMETRY [J].
CHASEY, KL ;
ACZEL, T .
ENERGY & FUELS, 1991, 5 (03) :386-394
[9]  
Chen L, 1987, Rapid Commun Mass Spectrom, V1, P39, DOI 10.1002/rcm.1290010303
[10]   PHASE-MODULATED STORED WAVE-FORM INVERSE FOURIER-TRANSFORM EXCITATION FOR TRAPPED ION MASS-SPECTROMETRY [J].
CHEN, L ;
WANG, TCL ;
RICCA, TL ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :449-454