Subsecond multisection CT of regional pulmonary ventilation

被引:68
作者
Tajik, JK
Chon, D
Won, C
Tran, BQ
Hoffman, EA
机构
[1] Univ Iowa, Coll Med, Dept Physiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Coll Med, Dept Biomed Engn, Iowa City, IA 52242 USA
[3] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA 52242 USA
关键词
computed tomography (CT); electron beam; experimental; lung; CT; ventilation; xenon;
D O I
10.1016/S1076-6332(03)80163-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To evaluate the adequacy of multibreath and single-breath stable xenon gas techniques to measure regional ventilation during cardiac-gated, high-speed, multisection imaging, the authors carried out a series of studies using electron-beam computed tomography (CT) and a recently introduced subsecond multisection spiral CT scanner. Materials and Methods. In four anesthetized pigs, the authors implemented single-breath and/or dynamic multibreath wash-in and washout protocols with respiratory- and cardiac-gated image acquisition. The effects of varying tidal volume and inspiratory flow rate were evaluated independently. Scanning was done at end expiration to avoid artifacts from partial volumed conducting airways, which are filled with inspired gas concentration during inspiration. Results. A single breath of 100% xenon provides adequate enhancement in the lung parenchyma (mean, 32 HU +/- 1.85 [standard error]) and should not cause unwanted side effects (mean xenon concentration in lung periphery, 21%). The single-breath method is suitable for studies requiring only short periods of apnea. Using the multibreath method, in dependent portions of the lung, there was close agreement between measured changes and predictions based on the xenon calibration data. More than 10 breaths were needed to clear tracer from poorly ventilated areas. and some nondependent regions demonstrated apparently "linear" rather than exponential clearance curves, possibly reflecting longer washout times. Analysis of wash-in and washout curves revealed vertical ventilation gradients, and at higher inspiratory flow rates, redistribution of ventilation to areas of the lung with greater pathway conductance. Conclusion. With careful attention to lung volume and use of cardiac gating. it is no possible to correlate lung structure with function to a degree heretofore not possible.
引用
收藏
页码:130 / 146
页数:17
相关论文
共 34 条
  • [1] ASSESSMENT OF METHACHOLINE-INDUCED AIRWAY CONSTRICTION BY ULTRAFAST HIGH-RESOLUTION COMPUTED-TOMOGRAPHY
    AMIRAV, I
    KRAMER, SS
    GRUNSTEIN, MM
    HOFFMAN, EA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) : 2239 - 2250
  • [2] Awai K, 1990, Rinsho Hoshasen, V35, P847
  • [3] EFFECT OF INSPIRATORY FLOW-RATE ON REGIONAL DISTRIBUTION OF INSPIRED GAS
    BAKE, B
    WOOD, L
    MURPHY, B
    MACKLEM, PT
    MILICEMI.J
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (01) : 8 - 17
  • [4] CARDIAC COMPUTED-TOMOGRAPHY
    BOYD, DP
    LIPTON, MJ
    [J]. PROCEEDINGS OF THE IEEE, 1983, 71 (03) : 298 - 307
  • [5] THE ANESTHETIC PROPERTIES OF XENON IN ANIMALS AND HUMAN BEINGS, WITH ADDITIONAL OBSERVATIONS ON KRYPTON
    CULLEN, SC
    GROSS, EG
    [J]. SCIENCE, 1951, 113 (2942) : 580 - 582
  • [6] REGIONAL PULMONARY VENTILATION MEASUREMENTS BY XENON ENHANCED DYNAMIC COMPUTED-TOMOGRAPHY - AN UPDATE
    GUR, D
    SHABASON, L
    BOROVETZ, HS
    HERBERT, DL
    REECE, GJ
    KENNEDY, WH
    SERAGO, C
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (05) : 678 - 683
  • [7] GUR D, 1979, J COMPUT ASSIST TOMO, V3, P749
  • [8] MAPPING OF HUMAN LOCAL PULMONARY VENTILATION BY XENON ENHANCED COMPUTED-TOMOGRAPHY
    HERBERT, DL
    GUR, D
    SHABASON, L
    GOOD, WF
    RINALDO, JE
    SNYDER, JV
    BOROVETZ, HS
    MANCICI, MC
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (06) : 1088 - 1093
  • [9] MATCHING PULMONARY STRUCTURE AND PERFUSION VIA COMBINED DYNAMIC MULTISLICE CT AND THIN-SLICE HIGH-RESOLUTION CT
    HOFFMAN, EA
    TAJIK, JK
    KUGELMASS, SD
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1995, 19 (01) : 101 - 112
  • [10] Assessment of the pulmonary structure-function relationship and clinical outcomes measures: Quantitative volumetric CT of the lung
    Hoffman, EA
    McLennan, G
    [J]. ACADEMIC RADIOLOGY, 1997, 4 (11) : 758 - 776