Enhancement of extraction efficiency and reduction of boundary layer effects in pulse introduction membrane extraction

被引:8
作者
Guo, XM [1 ]
Mitra, S [1 ]
机构
[1] New Jersey Inst Technol, Dept Chem Engn Chem & Environm Sci, Newark, NJ 07102 USA
关键词
D O I
10.1021/ac990352s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Membrane separation has emerged as an attractive alternative for interfacing an extraction step directly to a gas chromatograph or to a mass spectrometer. In pulse introduction (or now injection type) membrane extraction, a sample pulse is introduced onto an eluent stream that transports it onto the membrane. Since a fixed sample volume is injected, the detector response is directly proportional to the extraction efficiency. This in turn depends on membrane module design, flow conditions, etc. Also, when water contacts a membrane, a static boundary layer is formed at the membrane surface that serves as an additional diffusional barrier to the permeation process. Consequently, permeation slows down, which lowers the speed of analysis, In this paper, methods of increasing the extraction efficiency and decreasing boundary layer effects are presented. The goal is to have higher sensitivity at a shorter analysis time. A stream of nitrogen is introduced into the membrane after sample elution to eliminate the aqueous boundary layer. This technique is found to be effective not only for faster analysis, but also for increasing extraction efficiency.
引用
收藏
页码:4407 / 4412
页数:6
相关论文
共 20 条
[1]  
GUO X, UNPUB ANAL CHEM
[2]   Development of pulse introduction membrane extraction for analysis of volatile organic compounds in individual aqueous samples, and for continuous on-line monitoring [J].
Guo, XM ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (01) :39-47
[3]  
KOTIAHO T, 1991, Analytical Chemistry, V63, P875
[4]  
LEE BI, 1977, PROPERTIES GASES LIQ
[5]   CONTINUOUS GAS-CHROMATOGRAPHIC MONITORING OF LOW CONCENTRATION SAMPLE STREAMS USING AN ONLINE MICROTRAP [J].
MITRA, S ;
YUN, C .
JOURNAL OF CHROMATOGRAPHY, 1993, 648 (02) :415-421
[6]   A SEQUENTIAL VALVE-MICROTRAP INJECTION SYSTEM FOR CONTINUOUS, ONLINE GAS-CHROMATOGRAPHIC ANALYSIS AT TRACE LEVELS [J].
MITRA, S ;
LAI, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (06) :285-289
[7]   Continuous monitoring of volatile organic compounds in air emissions using an on-line membrane extraction-microtrap-gas chromatographic system [J].
Mitra, S ;
Zhu, NH ;
Zhang, X ;
Kebbekus, B .
JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) :165-173
[8]  
Mitra S, 1998, ANAL LETT, V31, P367
[9]  
Mitra S, 1996, J MICROCOLUMN SEP, V8, P21, DOI 10.1002/(SICI)1520-667X(1996)8:1<21::AID-MCS4>3.0.CO
[10]  
2-A