Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic

被引:252
作者
Shah, S
Chatterjee, A
Mathai, M
Kelly, SP
Kwartz, J
Henson, D
McLeod, D
机构
[1] Univ Copenhagen, Herlev Hosp, Dept Ophthalmol, Copenhagen, Denmark
[2] Royal Bolton Hosp, Eye Dept, Bolton, England
[3] Univ Manchester, Royal Eye Hosp, Dept Ophthalmol, Manchester, Lancs, England
[4] Optimax Laser Eye Clin, Manchester, Lancs, England
关键词
D O I
10.1016/S0161-6420(99)90498-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To assess whether central corneal thickness (CCT) is a confounding factor in the classification of patients attending for glaucoma assessment in a district general hospital. Design: Cross-sectional study by a single observer. Participants: Patients attending a general ophthalmic clinic: 235 clinically normal eyes, 52 eyes with normal-tension glaucoma (NTG), 335 eyes with primary open-angle glaucoma (POAG), 12 eyes with pseudoexfoliative glaucoma (PXE), 42 eyes with chronic angle closure glaucoma (CACG), and 232 glaucoma suspect (GS) eyes. Intervention: Central corneal thickness was measured using ultrasonic pachymetry. Main Outcome Measure: Correlation of CCT and diagnosis. Results: Mean CCT was 553.9 mu m (95% confidence intervals [Cl] for the mean, 549.0-558.8 mu m) in the clinically normal eyes, 550.1 mu m (95% Cl, 546.6-553.7 mu m) in the POAG eyes, 514.0 mu m (95% Cl, 504.8-523.3 mu m) in the NTG eyes, 530.7 mu m (95% Cl, 511.2-550.1 mu m) in the PXE eyes, 559.9 mu m (95% Cl, 546.8-573.0 mu m) in the CACG eyes, and 579.5 mu m (95% Cl, 574.8-584.1 mu m) in the GS eyes. The differences of mean CCT between the groups were highly significant (P < 0.001 analysis of variance). Eighty-five percent of eyes with NTG and only 36% of eyes with POAG had a mean CCT of 540 mu m or less. Thirteen percent of eyes with POAG and 42% of GS eyes had a mean CCT greater than 585 mu m. Conclusions: The CCT measurement is desirable in patients attending for glaucoma assessment in a district general hospital to avoid misclassification resulting from the relationship between CCT and tonometric pressure. Central corneal thickness alone is not an accurate predictor for the clinical diagnosis in this group of eyes. However, many eyes diagnosed as having NTG have thin corneas, which would tend to lower the tonometrically recorded intraocular pressure (IOP), so the finding of a less-than-normal thickness cornea introduces some doubt as to the diagnosis of NTG, For the GS eyes, most eyes had thick corneas, which would tend to increase the tonometrically recorded IOP, Thus, GS eyes with modest elevation of IOP and a thick cornea may be at low risk of progressing to POAG, Thus, many patients with "high IOPs" and a thick CCT do not necessarily have high IOPs and may not need to be followed as GS eyes.
引用
收藏
页码:2154 / 2160
页数:7
相关论文
共 9 条
[1]   Ocular hypertension and central corneal thickness [J].
Argus, WA .
OPHTHALMOLOGY, 1995, 102 (12) :1810-1812
[2]   Reduction in intraocular pressure after excimer laser photorefractive keratectomy - Correlation with pretreatment myopia [J].
Chatterjee, A ;
Shah, S ;
Bessant, DA ;
Naroo, SA ;
Doyle, SJ .
OPHTHALMOLOGY, 1997, 104 (03) :355-359
[3]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P652
[4]  
EHLERS N, 1974, ACTA OPHTHALMOL, V52, P740
[5]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[6]  
GOLDMANN H, 1957, Ophthalmologica, V134, P221
[7]  
HANSEN FK, 1971, ACTA OPHTHALMOL, V49, P82
[8]   THE EFFECT OF CORNEAL THICKNESS ON APPLANATION TONOMETRY [J].
WHITACRE, MM ;
STEIN, RA ;
HASSANEIN, K .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (05) :592-596
[9]   SOURCES OF ERROR WITH USE OF GOLDMANN-TYPE TONOMETERS [J].
WHITACRE, MM ;
STEIN, R .
SURVEY OF OPHTHALMOLOGY, 1993, 38 (01) :1-30