Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation

被引:50
作者
Bottiger, BW
Sinner, B
Motsch, J
Bach, A
Bauer, H
Martin, E
机构
[1] Department of Anaesthesia, University of Heidelberg, D-69120 Heidelberg
关键词
heart; cardiac output; measurement techniques; thermodilution; surgery; liver transplantation;
D O I
10.1111/j.1365-2044.1997.079-az0077.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We evaluated intermittent and continuous thermodilution cardiac output data in 12 patients undergoing orthotopic liver transplantation. Measurements were performed at 16 predefined time points between induction of anaesthesia and 3 h after reperfusion of the liver graft. Cardiac output measurements yielded 192 data pairs (intermittent cardiac output range: 1.8-18.91.min(-1), continuous cardiac output range: 3.3-20.01.min(-1)). During most of the procedure the correlation between intermittent and continuous cardiac output measurements was significant (r = 0.87, p < 0.0001), accompanied with a bias of -0.2401.min(-1) and a degree of precision of 1.7891.min(-1) ( < 10.01.min(-1) : 1.1371.min(-1), greater than or equal to 10.01.min(-1) : 2.2201.min(-1)). However, in the early phases after caval clamping and after reperfusion, accuracy was not acceptable. Only during these phases did the difference between the mean values of pulmonary artery blood temperature and rectal temperature increase (after caval clamping) or decrease (after reperfusion). In conclusion, despite acceptable levels of accuracy and precision between intermittent and continuous cardiac output measurement under stable conditions, both methods showed markedly decreased accuracy and precision in the early phases after caval damping and after reperfusion, possibly owing to increased thermal noise.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 26 条
[1]   POSTREPERFUSION SYNDROME - HYPOTENSION AFTER REPERFUSION OF THE TRANSPLANTED LIVER [J].
AGGARWAL, S ;
KANG, YG ;
FREEMAN, JA ;
FORTUNATO, FL ;
PINSKY, MR .
JOURNAL OF CRITICAL CARE, 1993, 8 (03) :154-160
[2]  
BAZERAL MG, 1992, ANESTHESIOLOGY, V77, P31
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
BOLDT J, 1994, CRIT CARE MED, V22, P1913
[5]  
Bottiger BW, 1996, INTENS CARE MED, V22, P312
[6]   CONTINUOUS VERSUS INTERMITTENT CARDIAC-OUTPUT MEASUREMENT IN CARDIAC SURGICAL PATIENTS UNDERGOING HYPOTHERMIC CARDIOPULMONARY BYPASS [J].
BOTTIGER, BW ;
RAUCH, H ;
BOHRER, H ;
MOTSCH, J ;
SODER, M ;
FLEISCHER, F ;
MARTIN, E .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (04) :405-411
[7]  
CARMICHAEL FJ, 1985, ANESTH ANALG, V64, P108
[8]  
DEWOLF A, 1993, TRANSPLANT P, V25, P1863
[9]  
DEWOLF AM, 1993, ANESTH ANALG, V76, P562
[10]  
ESTRIN JA, 1989, TRANSPLANT P, V21, P3500