Automatic Tuberculosis Screening Using Chest Radiographs

被引:392
作者
Jaeger, Stefan [1 ]
Karargyris, Alexandros [1 ]
Candemir, Sema [1 ]
Folio, Les [2 ]
Siegelman, Jenifer [3 ,4 ]
Callaghan, Fiona [1 ]
Xue, Zhiyun [1 ]
Palaniappan, Kannappan [5 ]
Singh, Rahul K. [5 ]
Antani, Sameer [1 ]
Thoma, George [1 ]
Wang, Yi-Xiang [6 ]
Lu, Pu-Xuan [7 ]
McDonald, Clement J. [1 ]
机构
[1] US Natl Lib Med, Lister Hill Natl Ctr Biomed Commun, Bethesda, MD 20894 USA
[2] NIH, Ctr Clin, Bethesda, MD 20892 USA
[3] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[4] Harvard Univ, Sch Med, Boston, MA 02115 USA
[5] Univ Missouri, Dept Comp Sci, Columbia, MO 65211 USA
[6] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Imaging & Intervent Radiol, Shatin, Hong Kong, Peoples R China
[7] Guangdong Med Coll, Shenzhen Peoples Hosp 3, Dept Radiol, Shenzhen 518020, Peoples R China
基金
美国国家卫生研究院;
关键词
Computer-aided detection and diagnosis; lung; pattern recognition and classification; segmentation; tuberculosis (TB); X-ray imaging; COMPUTER-AIDED DIAGNOSIS; INFECTIOUS PULMONARY TUBERCULOSIS; BINARY PATTERNS; LUNG NODULES; CLASSIFICATION; SEGMENTATION; SHAPE; RECOGNITION; INFORMATION; CLAVICLE;
D O I
10.1109/TMI.2013.2284099
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Tuberculosis is a major health threat in many regions of the world. Opportunistic infections in immunocompromised HIV/AIDS patients and multi-drug-resistant bacterial strains have exacerbated the problem, while diagnosing tuberculosis still remains a challenge. When left undiagnosed and thus untreated, mortality rates of patients with tuberculosis are high. Standard diagnostics still rely on methods developed in the last century. They are slow and often unreliable. In an effort to reduce the burden of the disease, this paper presents our automated approach for detecting tuberculosis in conventional posteroanterior chest radiographs. We first extract the lung region using a graph cut segmentation method. For this lung region, we compute a set of texture and shape features, which enable the X-rays to be classified as normal or abnormal using a binary classifier. We measure the performance of our system on two datasets: a set collected by the tuberculosis control program of our local county's health department in the United States, and a set collected by Shenzhen Hospital, China. The proposed computer-aided diagnostic system for TB screening, which is ready for field deployment, achieves a performance that approaches the performance of human experts. We achieve an area under the ROC curve (AUC) of 87% (78.3% accuracy) for the first set, and an AUC of 90% (84% accuracy) for the second set. For the first set, we compare our system performance with the performance of radiologists. When trying not to miss any positive cases, radiologists achieve an accuracy of about 82% on this set, and their false positive rate is about half of our system's rate.
引用
收藏
页码:233 / 245
页数:13
相关论文
共 73 条
[1]  
[Anonymous], 2008, P 16 INT C MULTIMEDI, DOI DOI 10.1145/1459359.1459577
[2]  
[Anonymous], 2009, MM 09 P 2009 ACM MUL, DOI DOI 10.1145/1631272.1631456
[3]  
[Anonymous], 2007, MATLAB VER 7 4 0 287
[4]  
[Anonymous], 2011, P 19 ACM INT C MULT
[5]   Dissimilarity-based classification in the absence of local ground truth: Application to the diagnostic interpretation of chest radiographs [J].
Arzhaeva, Y. ;
Tax, D. M. J. ;
van Ginneken, B. .
PATTERN RECOGNITION, 2009, 42 (09) :1768-1776
[6]  
Beard D., 2009, THESIS U MISSOURI CO
[7]   Rapid Molecular Detection of Tuberculosis and Rifampin Resistance [J].
Boehme, Catharina C. ;
Nabeta, Pamela ;
Hillemann, Doris ;
Nicol, Mark P. ;
Shenai, Shubhada ;
Krapp, Fiorella ;
Allen, Jenny ;
Tahirli, Rasim ;
Blakemore, Robert ;
Rustomjee, Roxana ;
Milovic, Ana ;
Jones, Martin ;
O'Brien, Sean M. ;
Persing, David H. ;
Ruesch-Gerdes, Sabine ;
Gotuzzo, Eduardo ;
Rodrigues, Camilla ;
Alland, David ;
Perkins, Mark D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (11) :1005-1015
[8]   Fast approximate energy minimization via graph cuts [J].
Boykov, Y ;
Veksler, O ;
Zabih, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2001, 23 (11) :1222-1239
[9]   Graph cuts and efficient N-D image segmentation [J].
Boykov, Yuri ;
Funka-Lea, Gareth .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2006, 70 (02) :109-131
[10]   Epifluorescence-based Quantitative Microvasculature Remodeling Using Geodesic Level-Sets and Shape-based Evolution [J].
Bunyak, F. ;
Palaniappan, K. ;
Glinskii, O. ;
Glinskii, V. ;
Glinsky, V. ;
Huxley, V. .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :3134-+