Preparation and evaluation of slurry-packed liquid chromatography microcolumns with inner diameters from 12 to 33 mu m

被引:106
作者
Hsieh, SC [1 ]
Jorgenson, JW [1 ]
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
关键词
D O I
10.1021/ac950682m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fused silica capillary liquid chromatography columns with inner diameters between 12 and 33 mu m were slurry packed with 5 mu m octadecysilane-modified silica particles. Column efficiencies and van Deemter coefficients were compared. A linear decrease of the A term as column diameter was decreased was the most significant contributor to a lower overall plate height at the optimum velocity.
引用
收藏
页码:1212 / 1217
页数:6
相关论文
共 15 条
[1]  
BOX GEP, 1977, STAT EXPT, P118
[2]   ON THE STABILITY OF MICRO-LC COLUMNS (PACKED FUSED-SILICA CAPILLARY COLUMNS) [J].
DEWEERDT, M ;
DEWAELE, C ;
VERZELE, M .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (10) :553-556
[3]   PERFORMANCE EVALUATION OF SLURRY-PACKED CAPILLARY COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
GLUCKMAN, JC ;
HIROSE, A ;
MCGUFFIN, VL ;
NOVOTNY, M .
CHROMATOGRAPHIA, 1983, 17 (06) :303-309
[4]   TECHNIQUE FOR ACCURATE MEASUREMENT OF CAPILLARY LENGTHS AND DIAMETERS [J].
GUTHRIE, EJ ;
JORGENSON, JW ;
KNECHT, LA ;
BUSH, SG .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (10) :566-567
[5]   PACKED CAPILLARY COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
HOFFMANN, S ;
BLOMBERG, L .
CHROMATOGRAPHIA, 1987, 24 :416-420
[6]   LIQUID-CHROMATOGRAPHY IN OPEN-TUBULAR COLUMNS - THEORY OF COLUMN OPTIMIZATION WITH LIMITED PRESSURE AND ANALYSIS TIME, AND FABRICATION OF CHEMICALLY BONDED REVERSED-PHASE COLUMNS ON ETCHED BOROSILICATE GLASS-CAPILLARIES [J].
JORGENSON, JW ;
GUTHRIE, EJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :335-348
[7]   SEPARATION EFFICIENCY OF SLURRY-PACKED LIQUID-CHROMATOGRAPHY MICROCOLUMNS WITH VERY SMALL INNER DIAMETERS [J].
KARLSSON, KE ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1662-1665
[8]   PREPARATION AND EVALUATION OF PACKED CAPILLARY LIQUID-CHROMATOGRAPHY COLUMNS WITH INNER DIAMETERS FROM 20-MU-M TO 50-MU-M [J].
KENNEDY, RT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1128-1135
[9]   PNEUMATIC MICROSYRINGE FOR USE AS AN INJECTOR IN OPEN TUBULAR LIQUID-CHROMATOGRAPHY AND AS A DISPENSER IN MICROANALYSIS [J].
KENNEDY, RT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1988, 60 (15) :1521-1524
[10]   EFFECT OF COLUMN TO PARTICLE DIAMETER RATIO ON DISPERSION OF UNSORBED SOLUTES IN CHROMATOGRAPHY [J].
KNOX, JH ;
PARCHER, JF .
ANALYTICAL CHEMISTRY, 1969, 41 (12) :1599-&