Application of transmission near-infrared spectroscopy to uniformity of content testing of intact steroid tablets

被引:45
作者
Broad, NW
Jee, RD
Moffat, AC
Smith, MR
机构
[1] Univ London, Sch Pharm, Ctr Pharmaceut Anal, London WC1N 1AX, England
[2] Abbott Labs, Queenborough ME11 5EL, Kent, England
关键词
D O I
10.1039/b106741a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Transmission near-infrared (NIR) spectroscopy was used for the rapid and non-destructive determination of the content of a hormone steroid in single intact tablets. Tablets produced for clinical trial purposes containing 5, 10, 15, 20 and 30 mg (2.94, 5.88, 8.82, 11.76 and 17.64% m/m, respectively) were used to develop calibration models without the need to specially prepare any out of specification tablets. Reference values for the individual tablets used in the NIR calibration models and test set were measured by reversed-phase high performance liquid chromatography (HPLC). Partial least squares regression using standard normal variate transformed second-derivative spectra over the range 800 to 1040 nm gave the optimum calibration model with a standard error of calibration of 0.52 mg per tablet. Measurements of an independent test set gave comparable results (standard error of prediction 0.31 mg per tablet). Measurement errors for a single tablet (RSD < 2.5% for a given active level) were sufficiently small to allow the procedure to be applied to pharmacopoeial uniformity of content testing of batches of these tablets and permitted the non-destructive testing of 30 tablets in under 20 min as compared to 6 h by HPLC.
引用
收藏
页码:2207 / 2211
页数:5
相关论文
共 23 条
[1]  
Adams MJ., 1995, CHEMOMETRICS ANAL SP
[2]  
[Anonymous], 2000, US PHARM
[3]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[4]   Near-infrared analytical control of pharmaceuticals. A single calibration model from mixed phase to coated tablets [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Serrano, D .
ANALYST, 1998, 123 (11) :2307-2312
[5]   Analytical control of pharmaceutical production steps by near infrared reflectance spectroscopy [J].
Blanco, M ;
Coello, J ;
Eustaquio, A ;
Iturriaga, H ;
Maspoch, S .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :237-246
[6]   Strategies for constructing the calibration set in the determination of active principles in pharmaceuticals by near infrared diffuse reflectance spectrometry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
delaPezuela, C .
ANALYST, 1997, 122 (08) :761-765
[7]   Development and validation of a near infrared method for the analytical control of a pharmaceutical preparation in three steps of the manufacturing process [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pou, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (05) :534-539
[8]  
CORTI P, 1990, ANALUSIS, V18, P112
[9]   Determination of paracetamol in intact tablets by use of near infrared transmittance spectroscopy [J].
Eustaquio, A ;
Blanco, M ;
Jee, RD ;
Moffat, AC .
ANALYTICA CHIMICA ACTA, 1999, 383 (03) :283-290
[10]   Quantification of paracetamol in intact tablets using near-infrared transmittance spectroscopy [J].
Eustaquio, A ;
Graham, P ;
Jee, RD ;
Moffatt, AC ;
Trafford, AD .
ANALYST, 1998, 123 (11) :2303-2306