Design and validation of a tool for neurite tracing and analysis in fluorescence microscopy images

被引:1201
作者
Meijering, E
Jacob, M
Sarria, JCF
Steiner, P
Hirling, H
Unser, M
机构
[1] Erasmus Univ, Med Ctr Rotterdam, Biomed Imaging Grp Rotterdam, Dept Med Informat, NL-3000 DR Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr Rotterdam, Biomed Imaging Grp Rotterdam, Dept Radiol, NL-3000 DR Rotterdam, Netherlands
[3] Swiss Fed Inst Technol, Inst Biomed Imaging Opt & Engn, CH-1015 Lausanne, Switzerland
[4] Swiss Fed Inst Technol, Inst Neurosci, CH-1015 Lausanne, Switzerland
关键词
cell culture; neurite outgrowth; fluorescence microscopy; neurite tracing; interactive segmentation; pattern recognition; computer-assisted image analysis; software validation;
D O I
10.1002/cyto.a.20022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: For the investigation of the molecular mechanisms involved in neurite outgrowth and differentiation, accurate and reproducible segmentation and quantification of neuronal processes are a prerequisite. To facilitate this task, we developed a semiautomatic neurite tracing technique. This article describes the design and validation of the technique. Methods: The technique was compared to fully manual delineation. Four observers repeatedly traced selected neurites in 20 fluorescence microscopy images of cells in culture, using both methods. Accuracy and reproducibility were determined by comparing the tracings to high-resolution reference tracings, using two error measures. Labor intensiveness was measured in numbers of mouse clicks required. The significance of the results was determined by a Student t-test and by analysis of variance. Results: Both methods slightly underestimated the true neurite length, but the differences were not unanimously significant. The average deviation from the true neurite centerline was a factor 2.6 smaller with the developed technique compared to fully manual tracing. Intraobserver variability in the respective measures was reduced by a factor 6.0 and 23.2. Interobserver variability was reduced by a factor 2.4 and 8.8, respectively, and labor intensiveness by a factor 3.3. Conclusions: Providing similar accuracy in measuring neurite length, significantly improved accuracy in neurite centerline extraction, and significantly improved reproducibility and reduced labor intensiveness, the developed technique may replace fully manual tracing methods. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 30 条
[1]   Rapid automated three-dimensional tracing of neurons from confocal image stacks [J].
Al-Kofahi, KA ;
Lasek, S ;
Szarowski, DH ;
Pace, CJ ;
Nagy, G ;
Turner, JN ;
Roysam, B .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2002, 6 (02) :171-187
[2]  
Altman D.G., 1991, Practical Statistics for Medical Research, DOI [10.1002/sim.4780101015, DOI 10.1002/SIM.4780101015]
[3]  
Barrett W A, 1997, Med Image Anal, V1, P331, DOI 10.1016/S1361-8415(97)85005-0
[4]   A rapid method for semi-quantitative analysis of neurite outgrowth from chick DRG explants using image analysis [J].
Bilsland, J ;
Rigby, M ;
Young, L ;
Harper, S .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 92 (1-2) :75-85
[5]  
Can A, 1999, IEEE Trans Inf Technol Biomed, V3, P125, DOI 10.1109/4233.767088
[6]  
Capowski J.J., 1989, COMPUTER TECHNIQUES
[7]  
Cormen T. H., 2001, Introduction to Algorithms, V2nd
[8]   Automatic segmentation and skeletonization of neurons from confocal microscopy images based on the 3-D wavelet transform [J].
Dima, A ;
Scholz, M ;
Obermayer, K .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2002, 11 (07) :790-801
[9]   User-steered image segmentation paradigms: Live wire and live lane [J].
Falcao, AX ;
Udupa, JK ;
Samarasekera, S ;
Sharma, S ;
Hirsch, BE ;
Lotufo, RDA .
GRAPHICAL MODELS AND IMAGE PROCESSING, 1998, 60 (04) :233-260
[10]   An ultra-fast user-steered image segmentation paradigm: Live wire on the fly [J].
Falcao, AX ;
Udupa, JK ;
Miyazawa, FK .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (01) :55-62